CSM_H7CX_DS_E_2_1
1
Contents
Multifunction Counter
H7CX-A............................................................ 2
Tachometer
H7CX-R............................................................ 42
Common to All Models
Safety Precautions ........................................... 59
H7CX Series
H7CX-A H7CX-R
Multifunction Counter
Preset Counter
Total Counter
Batch Counter
Dual Counter
Tachometer
Tachometer
Multifunction Counter/Tachometer (DIN 48 × 48)
H7CX Series
DIN 48 x 48 Multifunction Counter/Tachometer with a Bright, Easy-to-view Negative
Transmissive LCD. The H7CX Defines a New Standard.
Highly visible display with backlit negative transmissive LCD.
Easy to check the output status from a long distance with changing display colors*1 (red/green).
Easy operation with a key for each digit.
All basic settings can be made with the DIP switches.
Includes preset counter, batch counter, dual counter, and tachometer.*2
Compatible with a wide variety of inputs, such as NPN/PNP universal input and DC 2-wire Sensors.
Certification: UL, CSA, and CE Marking.
Complies with NEMA4 (equivalent to IP66) (when using the Y92S-29 Waterproof Packing).
*1: Not supported by the H7CX-A11@/-R11@.
*2: The functions that can be selected depend on the model.
Refer to Safety Precautions on page 59.
2
Multifunction Preset Counter
H7CX-A
DIN 48 × 48 mm Multifunction Preset Counter
with a Bright, Easy-to-view, Negative
Transmissive LCD
Programmable PV color to visually alert when output status
changes (screw terminal block models).
Configurable as 1-stage counter, 2-stage counter, total and pre-
set counter, batch counter, dual counter, or tachometer. (Config-
urability varies with model.)
Meets a variety of mounting requirements:
Screw terminal block models, and pin-style terminal models.
Six-language instruction manual.
Contents
Model Number Structure.............................................................. 3
Ordering Information.................................................................... 3
Specifications............................................................................... 4
Connections................................................................................. 8
Nomenclature .............................................................................. 12
Dimensions .................................................................................. 13
Operating Procedures.................................................................. 17
Setting Procedure Guide ....................................................... 17
Operating Procedures (Counter Function) ............................ 18
Operating Procedures (Tachometer Function) ...................... 30
Operation in Configuration Selection Mode........................... 36
Additional Information .................................................................. 37
H7CX-A
3
Model Number Structure
Model Number Legend
Note: Some combinations are not available.
1. External connection
None: Screw terminals
11: 11-pin socket
2. No. of digits
None: 6 digits
4: 4 digits
3. Stage setting
None: 1-stage setting
U: Factory-set to 1-stage setting
W: Factory-set to 2-stage setting
4. Output type
None: Contact output or contact and transistor in combination
S: Transistor output
5. Supply voltage/external power supply
None: 100 to 240 VAC at 50/60 Hz with 12 VDC power supply
D: 12 to 24 VDC without external power supply
D1: 12 to 24 VDC or 24 VAC at 50/60 Hz with 12 VDC power
supply
6. Case color
None: Black
G: Light gray (Munsell 5Y7/1): Produced upon request.
Ordering Information
List of Models
Note: Can be used as a 2-stage counter. In this case, each output can be flexibly allocated to either stage 1 or 2.
Accessories (Order Separately)
Note: 1. Supplied with screw-terminal models (i.e., excluding H7CX-A11@/-A114@ models).
2. Y92A-48G is a finger-safe terminal cover attached to the P3GA-11 Socket.
1 2 3 4 5 6
H7CX-A@@@@@@
Supported configurations 1-stage counter
1-stage counter with total counter
1-stage counter
2-stage counter
1-stage counter with total
counter
1-stage counter with batch
counter
Dual counter (addition/subtrac-
tion)
Ta c h o m e t e r
1-stage counter
2-stage counter
1-stage counter
with total counter
1-stage counter
with batch counter
Dual counter (addi-
tion only)
Sensor
power
supply
Output type Supply voltage 11-pin socket Screw terminal
1-stage 1-stage
(See note.)
2-stage
6 digits 4 digits 6 digits 4 digits 6 digits 6 digits 4 digits
H7CX-A11@H7CX-A114@H7CX-A@H7CX-A4@H7CX-AU@H7CX-AW@H7CX-A4W@
12 VDC Contact output 100 to 240 VAC H7CX-A11 H7CX-A114 H7CX-A H7CX-A4 --- H7CX-AW H7CX-A4W
12 to 24 VDC/
24 VAC
H7CX-A11D1 H7CX-A114D1 --- --- --- H7CX-AWD1 ---
Contact and
transistor output
100 to 240 VAC --- --- --- --- H7CX-AU --- ---
12 to 24 VDC/
24 VAC
--- --- --- --- H7CX-AUD1 --- ---
Transistor output 100 to 240 VAC H7CX-A11S H7CX-A114S H7CX-AS H7CX-A4S --- H7CX-AWS ---
12 to 24 VDC/
24 VAC
H7CX-A11SD1 --- --- --- H7CX-AUSD1 H7CX-AWSD1 ---
None Contact output 12 to 24 VDC --- --- H7CX-AD H7CX-A4D --- --- ---
Transistor output --- --- H7CX-ASD H7CX-A4SD --- H7CX-AWSD H7CX-A4WSD
Name Models
Flush Mounting Adapter (See note 1.) Y92F-30
Waterproof Packing (See note 1.) Y92S-29
Track Mounting/Front Connecting
Socket
11-pin P2CF-11
11-pin, finger-safe type P2CF-11-E
Back Connecting Socket 11-pin P3GA-11
11-pin, finger-safe type P3GA-11 with Y92A-48G (See note 2.)
Hard Cover Y92A-48
Soft Cover Y92A-48F1
Mounting Track 50 cm (l) × 7.3 mm (t) PFP-50N
1 m (l) × 7.3 mm (t) PFP-100N
1 m (l) × 16 mm (t) PFP-100N2
End Plate PFP-M
Spacer PFP-S
H7CX-A
4
Specifications
Ratings
Note: 1. Permissible ripple: 20% (p-p) max.
2. The display is lit only when the power is ON.
3. Only when the following modes are selected.
Input mode: command, individual, or quadrature; output mode: K-2, D, or L
Item H7CX-A4@H7CX-A@H7CX-A114@H7CX-A11@
Classification Preset counter
Supported
configurations
1-stage counter, 1-stage counter with total counter (selectable)
Rated supply voltage
(See note 1.)
100 to 240 VAC (50/60 Hz), 12 to 24 VDC 100 to 240 VAC (50/60 Hz)
24 VAC (50/60 Hz)/12 to 24 VDC
Operating voltage range 85% to 110% of rated supply voltage (90% to 110% at 12 VDC)
Power consumption Approx. 9.2 VA at 264 VAC
Approx. 7.2 VA at 26.4 VAC
Approx. 3.7 W at 12 VDC
Mounting method Flush mounting Flush mounting, surface mounting, or DIN track mounting
External connections Screw terminals 11-pin socket
Terminal screw
tightening torque
0.5 N·m max. ---
Display
(See note 2.)
7-segment, negative transmissive LCD
PV 11.5-mm-high characters, red or
green (programmable)
9-mm-high characters, red or
green (programmable)
11.5-mm-high characters, red 9-mm-high characters, red
SV 6-mm-high characters, green
Digits 4 digits (999 to 9,999)
SV range: 0 to 9,999
6 digits (99,999 to 999,999)
SV range: 99,999 to 999,999
(See note 3.) or 0 to 999,999
4 digits (999 to 9,999)
SV range: 0 to 9,999
6 digits (99,999 to 999,999)
SV range: 99,999 to 999,999
(See note 3.) or 0 to 999,999
Max. counting speed 30 Hz or 5 kHz (selectable, ON/OFF ratio 1:1), common setting for CP1 and CP2
Input modes Increment, decrement, command, individual, and quadrature
Input signals CP1, CP2, reset, and total reset
Input method No-voltage input/voltage input (switchable)
No-voltage input
ON impedance: 1 k max. (Leakage current: 5 to 20 mA at 0 )
ON residual voltage: 3 V max.
OFF impedance: 100 k min.
Voltage input
High (logic) level: 4.5 to 30 VDC
Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 k)
Reset input Minimum reset input signal width: 1 or 20 ms (selectable), common setting for all inputs
Reset system External, manual, and automatic reset (internal according to C, R, P, and Q mode operation)
Output modes N, F, C, R, K-1, P, Q, A N, F, C, R, K-1, P, Q, A,
K-2, D, L
N, F, C, R, K-1, P, Q, A N, F, C, R, K-1, P, Q, A,
K-2, D, L
One-shot output time 0.01 to 99.99 s
Output type Contact type: SPDT
Transistor type: 1 transistor
Control output Contact output: 3 A at 250 VAC/30 VDC, resistive load (cosφ=1)
Minimum applied load: 10 mA at 5 VDC (failure level: P, reference value)
Transistor output: NPN open collector, 100 mA at 30 VDC
Residual voltage: 1.5 VDC max. (approx. 1 V)
Leakage current: 0.1 mA max.
NEMA B300 Pilot Duty, 1/4 HP 3-A resistive load at 120 VAC, 1/3 HP 3-A resistive load at 240 VAC
External power supply 12 VDC (±10%), 100 mA (except for H7CX-A@D models)
Refer to Safety Precautions (Common) on page 59 for details.
Key protection Ye s
Prescaling function Yes (0.001 to 9.999) Yes (0.001 to 99.999) Yes (0.001 to 9.999) Yes (0.001 to 99.999)
Decimal point
adjustment
Yes (rightmost 3 digits)
Sensor waiting time 250 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.)
Memory backup EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min.
Ambient temperature Operating: 10 to 55°C (10 to 50°C if counters are mounted side by side) (with no icing or condensation)
Storage: 25 to 65°C (with no icing or condensation)
Ambient humidity 25% to 85%
Case color Black (N1.5), light gray (Munsell 5Y7/1, produced upon request)
Attachments Waterproof packing, flush mounting adapter None
H7CX-A
5
Ratings (contd.)
Note: 1. Permissible ripple: 20% (p-p) max.
2. The display is lit only when the power is ON.
3. Only when the following modes are selected.
- Input mode: command, individual, or quadrature; output mode: K-2, D, L, or H
- Dual count calculating mode: SUB; output mode: K-2, D, L, or H in dual counter operation
Item H7CX-A4W@H7CX-AW@H7CX-AU@
Classification Preset counter Preset counter/tachometer
Supported configurations 1-stage counter, 2-stage counter, 1-stage
counter with total counter, 1-stage counter
with batch counter, dual counter (addition
only) (selectable)
1-stage counter, 2-stage counter, 1-stage counter with total counter, 1-stage counter with batch
counter, dual counter (addition/subtraction), tachometer (selectable)
Rated supply voltage (See note 1.) 100 to 240 VAC (50/60 Hz),
12 to 24 VDC
100 to 240 VAC (50/60 Hz),
24 VAC (50/60 Hz)/12 to 24 VDC,
12 to 24 VDC
100 to 240 VAC (50/60 Hz),
24 VAC (50/60 Hz)/12 to 24 VDC
Operating voltage range 85% to 110% of rated supply voltage (90% to 110% at 12 VDC)
Power consumption Approx. 9.2 VA at 264 VAC
Approx. 7.2 VA at 26.4 VAC
Approx. 3.7 W at 12 VDC
Mounting method Flush mounting
External connections Screw terminals
Terminal screw tightening torque 0.5 N·m max.
Display (See note 2.) 7-segment, negative transmissive LCD
PV 11.5-mm-high characters, red or green
(programmable)
9-mm-high characters, red or green (programmable)
SV 6-mm-high characters, green
Digits 4 digits (999 to 9,999)
SV range: 0 to 9,999
6 digits (99,999 to 999,999 or 0 to 999,999 when using as Tachometer)
SV range: 99,999 to 999,999 (See note 3.) or 0 to 999,999
Input signals CP1, CP2, reset 1, and reset 2
Input method No-voltage input/voltage input (switchable)
No-voltage input
ON impedance: 1 k max. (Leakage current: 5 to 20 mA at 0 )
ON residual voltage: 3 V max.
OFF impedance: 100 k min.
Voltage input
High (logic) level: 4.5 to 30 VDC
Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 k)
Counter Max. counting speed 30 Hz or 5 kHz (selectable, ON/OFF ratio 1:1), common setting for CP1 and CP2
Input mode Increment, decrement, command, individual, and quadrature
Reset input Minimum reset input signal width: 1 or 20 ms (selectable), common setting for all inputs
Reset system External, manual, and automatic reset (internal according to C, R, P, and Q mode operation)
Output modes N, F, C, R, K-1, P, Q, A N, F, C, R, K-1, P, Q, A, K-2, D, L, H
One-shot output time 0.01 to 99.99 s
Tachometer Pulse measurement
method
--- Periodic measurement (Sampling period: 200 ms)
Max. counting speed --- 30 Hz or 10 kHz (selectable)
Measuring ranges --- 30 Hz: 0.01 to 30.00 Hz
10 kHz: 0.01 Hz to 10 kHz
Measuring accuracy --- ±0.1% FS ±1 digit max. (at 23 ±5°C)
Output modes --- HI-LO, AREA, HI-HI, LO-LO
Auto-zero time --- 0.1 to 99.9 s
Startup time --- 0.0 to 99.9 s
Average processing --- OFF/2/4/8 times
Output type H7CX-A4W/-AW/-AWD1: SPDT (OUT2) and SPST-NO (OUT1)
H7CX-A4WSD/-AWS/-AWSD/-AWSD1: 2 transistors
H7CX-AU/-AUD1: SPDT and 1 transistor
H7CX-AUSD1: 2 transistors
(Output allocation possible)
Control output Contact output: 3 A at 250 VAC/30 VDC, resistive load (cosφ=1)
Minimum applied load: 10 mA at 5 VDC (failure level: P, reference value)
Transistor output: NPN open collector, 100 mA at 30 VDC
Residual voltage: 1.5 VDC max. (approx. 1 V)
Leakage current: 0.1 mA max.
NEMA B300 Pilot Duty, 1/4 HP 3-A resistive load at 120 VAC, 1/3 HP 3-A resistive load at 240 VAC
External power supply 12 VDC (±10%), 100 mA (except for H7CX-A@D models)
Refer to Safety Precautions (Common) on page 59 for details.
Key protection Ye s
Prescaling function Yes (0.001 to 9.999) Yes (0.001 to 99.999)
Decimal point adjustment Yes (rightmost 3 digits)
Sensor waiting time 250 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.)
Memory backup EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min.
Ambient temperature Operating: 10 to 55°C (10 to 50°C if counters are mounted side by side) (with no icing or condensation)
Storage: 25 to 65°C (with no icing or condensation)
Ambient humidity 25% to 85%
Case color Black (N1.5), light gray (Munsell 5Y7/1, produced upon request)
Attachments Waterproof packing, flush mounting adapt-
er
Waterproof packing, flush mounting adapter, labels for counter/tachometer DIP switch settings
H7CX-A
6
Characteristics
Note: 1. To meet UL listing requirements with the H7CX-A11@ models, an OMRON P2CF-11-@ or P3GA-11 Socket must be mounted on the
H7CX. Otherwise, H7CX-A11@ models are considered to meet UL508 recognition requirements.
2. The Y92S-29 Waterproof Packing and Y92F-30 Flush Mounting Adapter are necessary to ensure IP66, NEMA4, and UL Type 4X water-
proofing between the H7CX and installation panel.
item H7CX
Insulation resistance 100 M min. (at 500 VDC) between current-carrying terminal and exposed non-current-carrying metal parts, and be-
tween non-continuous contacts
Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-current-carrying metal parts
2,000 VAC (for 100 to 240 VAC), 50/60 Hz for 1 min between power supply and input circuit (1,000 VAC for 24 VAC/
12 to 24 VDC)
1,000 VAC (for H7CX-@SD/-@SD1), 50/60 Hz for 1 min between control output, power supply, and input circuit
(2,000 VAC for models other than H7CX-@SD/-@SD1)
1,000 VAC, 50/60 Hz for 1 min between non-continuous contacts
Impulse withstand
voltage
3 kV (between power terminals) for 100 to 240 VAC, 1 kV for 24 VAC/12 to 24 VDC and 12 to 24 VDC
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) for 100 to 240 VAC,
1.5 kV for 24 VAC/12 to 24 VDC and 12 to 24 VDC
Noise immunity ±1.5 kV (between power terminals) for 100 to 240 VAC and 24 VAC/12 to 24 VDC, ±480 V for 12 to 24 VDC
±600 V (between input terminals)
Square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise)
Static immunity Destruction: 15 kV
Malfunction: 8 kV
Vibration resistance Destruction: 10 to 55 Hz with 0.75-mm single amplitude, 2 hours each in three directions
Malfunction: 10 to 55 Hz with 0.35-mm single amplitude, 10 min each in three directions
Shock resistance Destruction: 294 m/s2 each in three directions
Malfunction: 196 m/s2 each in three directions
Life expectancy Mechanical: 10,000,000 operations min.
Electrical: 100,000 operations min. (3 A at 250 VAC, resistive load)
See Life-test Curve on page 7.
Approved safety
standards
(See notes 1 and 2.)
UL508/Listing, UL 50 Type 4X for indoor use (enclosure rating)
CSA C22.2 No. 14, conforms to EN61010-1 (Pollution degree 2/overvoltage category II)
Conforms to VDE0106/P100 (finger protection).
EMC (EMI) EN61326
Emission Enclosure: EN55011 Group 1 class A
Emission AC mains: EN55011 Group 1 class A
(EMS) EN61326
Immunity ESD: EN61000-4-2: 4 kV contact discharge (level 2);
8 kV air discharge (level 3)
Immunity RF-interference: EN61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) (level 3);
10 V/m (Pulse-modulated, 900 MHz ±5 MHz) (level 3)
Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (level 3)
Immunity Burst: EN61000-4-4: 2 kV power-line (level 3);
1 kV I/O signal-line (level 4)
Immunity Surge: EN61000-4-5: 1 kV line to lines (power and output lines) (level 2);
2 kV line to ground (power and output lines) (level 3)
Immunity Voltage Dip/Interruption: EN61000-4-11: 0.5 cycle, 100% (rated voltage)
Degree of protection Panel surface: IP66, NEMA 4 (indoors), and UL Type 4X (indoors) (See note 2.)
Weight Approx. 140 g
H7CX-A
7
Life-test Curve (Reference Values)
Resistive Load Inductive Load
Reference: A current of 0.15 A max. can be switched at 125 VDC (cosφ=1) and current of 0.1 A max. can be switched if L/R=7 ms. In both cases,
a life of 100,000 operations can be expected. The minimum applicable load is 10 mA at 5 VDC (failure level: P).
Inrush Current (Reference Values)
1,000
700
500
300
100
70
50
01 2 34
250 VAC (cosφ=1)
Load current (A)
30 VDC (cosφ=1)
No. of operations (×103)
1,000
700
500
300
100
70
50
01 2 34
250 VAC (cosφ=0.4)
Load current (A)
30 VDC (L/R=7 ms)
No. of operations (×103)
Model Voltage Applied voltage Inrush current (peak value) Time
H7CX-A11/-AW 100 to 240 VAC 264 VAC 5.8 A 0.7 ms
H7CX-A11D1/-AWD1 24 VAC/12 to 24 VDC 26.4 VAC 10.4 A 1.2 ms
H7CX-AD 12 to 24 VDC 26.4 VDC 6.0 A 1.2 ms
H7CX-A
8
Connections
Block Diagram
Note: All models except for H7CX-@D (models with 12 to 24-VDC power supplies) have basic insulation.
I/O Functions
Using as a Counter
Note: 1. In increment mode or increment/decrement mode, the present value returns to 0; in decrement mode, the present value returns to the
set value with 1-stage models, and returns to set value 2 with 2-stage models.
2. The reset indicator will not be lit when the total reset or reset 2 input is ON.
Using as a Tachometer
Input circuit
Display circuit
(See note.)
Output circuit
(Basic
insulation) Power supply
circuit
(Basic
insulation)
Key switch
circuit
Internal control
circuit
Inputs CP1, CP2 In general (except for dual counter mode)
Reads counting signals
Increment, decrement, command, individual, and quadrature inputs accepted.
When used as a dual counter
Reads CP1 count signals with CP1 input and CP2 count signals with CP2 input.
Increment signals can be input.
Reset or Reset 1 In general (except for dual counter mode)
Resets present value and outputs (OUT2 when using the batch counter). (See note 1.)
Counting cannot be performed during reset/reset 1 input.
The reset indicator is lit during reset input.
When used as a dual counter
Resets the CP1 present value (to 0).
Counting for CP1 input cannot be performed during reset 1 input.
The reset indicator is lit during reset 1 input.
Total Reset or
Reset 2
(See note 2.)
When used as a 1-stage/2-stage counter
Does not operate (Not used).
When used as a total and preset counter
Resets the total count value.
Holds the total count value at 0 during total reset input.
When used as a batch counter
Resets the batch count value and batch output (OUT1).
Holds the batch count value at 0 during reset 2 input.
When used as a dual counter
Resets the CP2 present value.
Counting for CP2 input cannot be performed during reset 2 input.
Outputs OUT1, OUT2 Outputs take place according to designated output mode when corresponding preset is reached.
Inputs CP1, CP2 Reads counting signals. (CP2 input is not available.)
Reset 1, Reset 2 Holds the measurement value and outputs. (Reset 2 input is not available.)
The reset indicator is lit during hold.
Outputs OUT1, OUT2 Outputs signals according to the specified output mode when a set value is reached.
H7CX-A
9
Terminal Arrangement
Confirm that the power supply meets specifications before use.
Note: Do not connect unused terminals as relay terminals.
678910
11 12 13
()
(+)
0 V
12345
678910
11 12 13
(+)()
0 V
12345
678910
11 12 13
12345
()
(+)
0 V
678910
11 12 13
0 V
12345
(+)()
67
8
9
10
11
1
2
3
4
5
(+)
()
CP1
CP2
0 V
()
(+)
67
8
9
10
11
1
2
3
4
5
(+)
()
CP1
CP2
0 V
()
(+)
OUT OUT
OUT OUT
OUT OUT
Sensor, etc.
Unused Unused
12 VDC Unused Unused Unused
Note: Terminals 1 and 6 are connected internally.
Sensor, etc.
12 VDC
Unused Unused Unused Unused Unused
Note: Terminals 1 and 6 are connected internally.
Reset
Total reset
Sensor, etc.
12 VDC
External power supply
Internal circuit
Reset
Total reset
Sensor, etc.
12 VDC
External power supply
Internal circuit
H7CX-A/-A4
1-stage Contact Output
Reset
CP2
CP1
Total reset
External power
supply
H7CX-AS/-A4S
1-stage Transistor Output
Reset
CP2
CP1
Total reset
External power
supply
H7CX-A11/-A114/-A11D1/-A114D1
1-stage Contact Output
H7CX-AD/-A4D
1-stage Contact Output
Reset
CP2
CP1
Total reset
H7CX-ASD/-A4SD
1-stage Transistor Output
Reset
CP2
CP1
Total reset
H7CX-A11S/-A114S/-A11SD1
1-stage Transistor Output
H7CX-A
10
Input Circuits
CP1, CP2, Reset/Reset 1, and Total Reset/Reset 2 Input
Note: The circuit shown above is for no-voltage input (NPN input).
678910
11 12 13
(+)
()
12345
()
(+)
0 V
678910
11 12 13
(+)()
12345
()
(+)
0 V
678910
11 12 13
0 V
12345
(+)()
678910
11 12 13
(+)()
12345
()
(+)
0 V
678910
11 12 13
(+)()
12345
()
(+)
0 V
OUT1
OUT2
OUT1
OUT2
OUT1
OUT2
OUT1 or 2
OUT 1 or 2
OUT1 or 2
OUT 1 or 2
Sensor, etc.
12 VDC
Sensor, etc.
12 VDC
Unused
Note: 1. Terminals 1 and 6 are connected internally.
Sensor, etc.
12 VDC
Sensor, etc.
12 VDC
H7CX-AW/-A4W/-AWD1
2-stage Contact Output
Reset 1
CP2
CP1
Reset 2
External power
supply
H7CX-AWSD/-A4WSD
2-stage Transistor Output
Reset 1
CP2
CP1
Reset 2
H7CX-AU/-AUD1
1-stage Contact, 1-stage Transistor Output
Reset 1
CP2
CP1
Reset 2
External power
supply
Note: Each output can be flexibly allocated to either
stage 1 or 2 by setting in function selection mode.
H7CX-AWS/-AWSD1
2-stage Transistor Output
Reset 1
CP2
CP1
Reset 2
External power
supply
H7CX-AUSD1
1 or 2-stage Transistor Output
Reset 1
CP2
CP1
Reset 2
External power
supply
Note: Each output can be flexibly allocated to
either stage 1 or 2 in function selection
mode.
2. Do not connect unused terminals as relay terminals.
+14 V
1 k
IN Internal
circuit
H7CX-A
11
Input Connections
The inputs of the H7CX are no-voltage (short-circuit or open) inputs or voltage inputs.
When using as a tachometer, CP2 input and total reset/reset 2 input are not available.
No-voltage Inputs (NPN Inputs)
No-voltage Input Signal Levels Applicable Two-wire Sensor
Leakage current: 1.5 mA max.
Switching capacity: 5 mA min.
Residual voltage: 3 VDC max.
Operating voltage: 10 VDC
Voltage Inputs (PNP Inputs)
Voltage Input Signal Levels
High level (Input ON): 4.5 to 30 VDC
Low level (Input OFF): 0 to 2 VDC
Maximum applicable voltage: 30 VDC max.
Input resistance: Approx. 4.7 k
6 7 8 9
10
3 7 5 6 4
6 7 8 9
3 7 5 6
10
4
6 7 8 9
3 7 5 6
10
4
6 7 8 9
3 7 5 6
10
4
Open Collector
H7CX-A@
H7CX-A11@
Operates when the transistor turns ON.
0 V
Voltage Output
Sensor
Operates when the transistor turns ON.
Contact Input
Operates when the contact turns ON.
Input
Reset/reset 1 input
CP2 input
CP1 input
Total reset/reset 2 input
PLC or
sensor
0 V
Input
Reset/reset 1 input
CP2 input
CP1 input
Total reset/reset 2 input
H7CX-A@
H7CX-A11@
0 V
Input
Reset/reset 1 input
CP2 input
CP1 input
Total reset/reset 2 input
H7CX-A@
H7CX-A11@
H7CX-A@
Operates when the transistor turns ON.
H7CX-A11@
DC Two-wire Sensor
Input
Reset/reset 1 input
CP2 input
CP1 input
Total reset/reset 2 input
No-contact input Short-circuit level
Transistor ON
Residual voltage: 3 V max.
Impedance when ON: 1 k max.
(The leakage current is approx. 12 mA when
the impedance is 0 .)
Open level
Transistor OFF
Impedance when OFF: 100 k min.
Contact input Use contact which can adequately switch
5 mA at 10 V.
Maximum applicable voltage: 30 VDC max.
6 7 8 9
3 7 5 6
10
4
6 7 8 9
3 7 5 6
10
4
6 7 8 9
3 7 5 6
10
4
Sensor
H7CX-A@
Operates when the transistor turns OFF.
H7CX-A11@
Operates when the transistor turns ON.
Contact Input
Operates when the contact turns ON.
0 V
Input
Reset/reset 1 input
CP2 input
CP1 input
Total reset/reset 2 input
No-contact Input
(NPN Transistor)
No-contact Input
(PNP Transistor)
H7CX-A@
H7CX-A11@
0 V
Input
Reset/reset 1 input
CP2 input
CP1 input
Total reset/reset 2 input
Sensor
H7CX-A@
H7CX-A11@
0 V
Input
Reset/reset 1 input
CP2 input
CP1 input
Total reset/reset 2 input
H7CX-A
12
Nomenclature
Reset Operation by Reset Key
1
2
3
4
5
6
9
10
1
2
3
4
5
6
9
10
8
7
11
12
8
7
11
13 14
A
B
C
D
E
F
G
H
I
J
K
L
M
Indicators Operation Keys
Switches
Key Protection Indicator (Orange)
Set Value 1, 2 Stage Indicator
Front view of 4-digit model
Front view of 6-digit model
Down Keys: 1 to 4
Key Protect Switch
(Factory setting) OFF ON
DIP Switch
Reset Indicator (Orange)
Lit when the reset input (1) or reset key
is ON.
Control Output Indicator (Orange)
OUT: One stage
OUT1, OUT2: Two stages
Total Count Indicator
Lit when the total count value is
displayed.
Batch Indicator
Lit when the batch count value is
displayed.
Present Value (Main Display)
Character height: 11.5 mm (6-digit: 9mm)
Set Value (Sub-display)
Character height: 6 mm
Mode Key
Used to switch mode and setting items.
Reset Key
The operation of the reset function
depends on the configuration selected
as shown in the table below.
Up Keys: 1 to 4
(6-digit models: 1 to 6)
Configuration Reset operation
1-stage/2-stage
counter
Resets the present value and outputs.
Total and preset
counter
Resets the present value and outputs.
When the total count value is displayed, resets
the present value, the total count value, and
outputs.
Batch counter Resets the present value and OUT2.
When the batch count value is displayed,
resets the present value, the batch count
value, and outputs.
Dual counter Resets the CP1 present value, CP2 present val-
ue, dual count value, and outputs.
Tachometer Maintains the measured value and outputs (hold
function).
H7CX-A
13
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Counter (without Flush Mounting Adapter)
Screw-terminal Models with External Power Supplies (Flush Mounting)
Screw-terminal Models without External Power Supplies (Flush Mounting)
11-pin Socket Models (Flush Mounting/Surface Mounting)
100
6
48×48
44.8×44.8
Note: M3.5 terminal screw (effective length: 6 mm)
H7CX-A
H7CX-AS
H7CX-A4
H7CX-A4S
H7CX-AW
H7CX-AWS
H7CX-A4W
H7CX-AWD1
H7CX-AWSD1
H7CX-AU
H7CX-AUD1
H7CX-AUSD1
64
6
44.8×44.8
48×48
Note: M3.5 terminal screw (effective length: 6 mm)
H7CX-AD
H7CX-ASD
H7CX-A4D
H7CX-A4SD
H7CX-AWSD
H7CX-AWSD
72.5 14.4
6
48×48
44.8×44.8
H7CX-A11
H7CX-A11S
H7CX-A11D1
H7CX-A11SD1
H7CX-A114
H7CX-A114S
H7CX-A114D1
H7CX-A
14
Dimensions with Flush Mounting Adapter
Dimensions with Front Connecting Socket
Note: These dimensions vary with the kind of DIN track (reference value).
58
48 98.57.5
(51)
58
48 7.5
(51)
62.5
58
48 7.5
(51)
98.7
A
45+0.6
0
45+0.6
0
0
A = (48n 2.5)+1
Panel Cutouts
60 min.
60 min.
15 min.
n side by side mounting
Panel
Panel
Panel
Y92F-30 (provided)
Flush Mounting Adapter
Y92S-29 (provided)
Waterproof Packing
H7CX-A
H7CX-AS
H7CX-A4
H7CX-A4S
H7CX-AW
H7CX-AWS
H7CX-A4W
H7CX-AWD1
H7CX-AWSD1
H7CX-AU
H7CX-AUD1
H7CX-AUSD1
H7CX-AD
H7CX-ASD
H7CX-A4D
H7CX-A4SD
H7CX-AWSD
H7CX-A4WSD
Y92F-30 (provided)
Flush Mounting Adapter
H7CX-A11
H7CX-A11S
H7CX-A11D1
H7CX-A11SD1
H7CX-A114
H7CX-A114S
H7CX-A114D1
Y92S-29 (order separately)
Waterproof Packing
Y92F-30 (order separately)
Flush Mounting Adapter
P3GA-11
(order separately)
Back Connecting
Socket
Panel cutouts are as
shown below.
(according to DIN43700).
Note: 1. The mounting panel thickness
should be 1 to 5 mm.
2. To allow easier operability, it is
recommended that Adapters are
mounted so that the gap between
sides with hooks is at least 15 mm
(i.e., so that the panel cutout interval
is at least 60 mm).
3. It is possible to mount counters
side by side, but only in the
direction without the hooks.
If they are mounted side-by-side,
water-resistant specifications
cannot be ensured.
0
With Y92A-48F1 attached.
A = {48n2.5 + (n1) x 4}+1
0
With Y92A-48 attached.
A = (51n5.5)+1
11-pin Socket Models
(Adapter and Waterproof Packing Ordered Separately)
Screw-terminal Models without External Power Supplies
(Provided with Adapter and Waterproof Packing)
Screw-terminal Models with External Power Supplies
(Provided with Adapter and Waterproof Packing)
Y92S-29 (provided)
Waterproof Packing
112 109.7
P2CF-11
H7CX
-A11@
H7CX-A
15
Accessories (Order Separately)
Note: All units are in millimeters unless otherwise indicated.
40±0.2
7.8 34.5
35.4
4
7.8
4
40±0.2
35.4
30
54.5
3
1.2
Track Mounting/Front Connecting Socket
P2CF-11
Surface Mounting Holes
Two, 4.5 dia. or two, M4
70 max.
50 max. 31.2 max.
70 max.
50 max. 31.2 max.
Note: Track mounting is also possible.
P2CF-11-E (Finger-safe Terminal Type)
Conforming to VDE0106/P100
Eleven,
M3.5 x 7.5 sems
Two, 4.5-dia.
holes
Terminal Arrangement/
Internal Connections
(Top View)
Eleven,
M3.5 x 7.5 sems
Two, 4.5-dia.
holes
45
45
25.6
4.5 16.3 6.2
34
47.7 x 47.7 48 x 48
47.4
16.5 24.6 27.6
Back Connecting Socket
P3GA-11
27 dia.
Twelve, 6.4-dia. holes
Note: Finger protection can be ensured by using in combination with the Y92A-48G Terminal Cover.
Finger-safe Terminal Cover
Conforming to VDE0106/P100
Y92A-48G
(Attachment for P3GA-11
Socket)
Terminal Arrangement/
Internal Connections
(Bottom View)
H7CX-A
16
Note: 1. Depending on the operating environment, the condition of
resin products may deteriorate, and may shrink or become
harder. Therefore, it is recommended that resin products
are replaced regularly.
2. The H7CX’s panel surface is water-resistive (conforming to
IP66) and so even if drops of water penetrate the gaps be-
tween the keys, there will be no adverse effect on internal
circuits. If, however, there is a possibility of oil being present
on the operator’s hands, use the Soft Cover. The Soft Cover
ensures protection equivalent to IP54 against oil. Do not,
however, use the H7CX in locations where it would come in
direct contact with oil.
When using the Y92S-29, the degree of protection for the H7CX's
panel surface conforms to NEMA4, UL Type 4X, and IP66. (Depend-
ing on the operating environment, the condition of the panel may
deteriorate, shrink, or become harder. Therefore, regular replace-
ment is recommended.)
Hard Cover
Y92A-48
Soft Cover
Y92A-48F1
Y92F-30 Y92S-29
Flush Mounting Adapter
(provided with screw-terminal models)
Waterproof Packing
(provided with screw-terminal models)
4.5
15 25 25 25 25 *
10 10
7.3±0.15
35±0.3 27±0.15
1
4.5
15 25 25 25 25 15
10 10
1,000
27 24
16
29.2
11.5
50
11.5
10
6.2 1.8
1
35.5 35.3
1.8
1.3
4.8
5
16
12
44.3
16.5
10
34.8
35±0.3
Mounting Track
PFP-100N, PFP-50N PFP-100N2
End Plate
PFP-M
Spacer
PFP-S
Note: The values shown in parentheses are for the PFP-50N.
1,000 (500)
(See note.)
M4 x 8
pan head
screw
H7CX-A
17
Operating Procedures
Setting Procedure Guide
Setting for Counter Operation
(1-stage/2-stage Counter, Total and Preset Counter, Batch Counter, Dual Counter)
Note: 1. At the time of delivery, the H7CX is set to the 1-stage counter (2-stage counter for H7CX-AW@/-A4W@ models) configuration.
2. Set to output 2 time when using as a 2-stage counter or batch counter.
Setting for Tachometer Operation
Note: At the time of delivery, the H7CX is set to the 2-stage counter (1-stage counter for H7CX-AU@ models) configuration.
12345678
OFF
ON
When Using Basic Settings Only
When Using Settings Other than the Above When Using Advanced Functions
Other Settings Advanced Functions
Counting speed (30 Hz, 5 kHz)
Input mode (UP, DOWN)
Output mode (N, F, C, K-1)
One-shot output time (0.5 s, 0.05 s) (See note 2.)
Reset input signal width (20 ms, 1 ms)
NPN/PNP input mode (NPN, PNP)
Basic Settings The settings can be performed easily with the DIP switch.
For details on the setting methods, refer to page 18.
All the functions can be set with the operation keys.
For details on the setting methods, refer to page 19.
Input mode (UP/DOWN A, UP/DOWN B, UP/DOWN C)
Output mode (R, P, Q, A, K-2, D, L, H)
One-shot output time (except for 0.5 s and 0.05 s) (See note 2.)
Settings for advanced functions other than the basic
settings above can be performed with the operation keys.
For details on the setting methods, refer to page 19.
Dual count calculating mode
Output 1 time (for 2-stage counter)
Decimal point position
Prescale value
Display color
Output allocation
Key protect level
12345678
OFF
ON
When Using Basic Settings Only
When Using Advanced Functions
Advanced Functions
Counting speed (30 Hz, 10 kHz)
Output mode (HI-LO, AREA, HI-HI, LO-LO)
Average processing (OFF, 2, 4, 8 times)
NPN/PNP input mode (NPN, PNP)
Basic Settings The settings can be performed easily with the DIP switch.
For details on the setting methods, refer to page 30.
Settings for advanced functions other than the basic
settings above can be performed with the operation keys.
For details on the setting methods, refer to page 31.
Decimal point position
Prescale value
Auto-zero time
Startup time
Display color
Output allocation
Key protect level
H7CX-A
18
Operating Procedures (Counter Function)
Settings for Basic Operations
Note: Set to one-shot output 2 time when using as a 2-stage counter
or batch counter.
Easy Confirmation of Switch Settings Using Indicators
The ON/OFF status of the DIP switch pins can be
confirmed using the front display. For details, refer to page 36.
Note: 1. Be sure to set pin 1 of the DIP switch to ON. If it is set to OFF, the DIP switch settings will not be enabled.
2. Changes to DIP switch settings are enabled when the power is turned ON.
3. When setting input modes, output modes, or output times that cannot be set with the DIP switch, all of the settings have to be made using
the operation keys. For details on the setting methods, refer to page 19. When making settings using the operation keys, be sure to set
pin 1 of the DIP switch to OFF.
12345678
OFF
ON
Settings for basic functions can be performed with just the DIP switch.
Be sure to set pin 1 to ON.
Note: All of the pins are factory-set to OFF.
Item OFF ON
1 DIP switch settings en-
able/disable
Disabled Enabled
2 Counting speed 30 Hz 5 kHz
3 Input mode UP (increment) DOWN (decre-
ment)
4 Output mode Refer to the table on the right.
5
6 One-shot output time
(See note.)
0.5 s 0.05 s
7 Reset input signal width 20 ms 1 ms
8 NPN/PNP input mode NPN PNP
Pin 4 Pin 5 Output mode
OFF OFF N
ON OFF F
OFF ON C
ON ON K-1
Switching to Total and Preset Counter, Batch Counter, and Dual Counter Operation (See note.)
Configuration selection mode
Run mode
Power ON
(Tachometer)
Note: The configurations that can be selected vary with the model.
+
Advanced-Function Settings
The H7CX is factory-set to the 1-stage
counter (2-stage counter for
H7CX-AW@/-A4W@ models) configuration.
To change to a different configuration, use
the procedure shown on the right. For
details, refer to page 36.
Note: This includes changing to the
2-stage counter (or 1-stage counter)
configuration.
Hold down for
1 s min. (See note.)
(1-stage
counter)
(2-stage
counter)
(Total and
preset counter)
(Batch
counter)
(Dual
counter)
After making DIP switch settings for basic operations, advanced functions (see note) can be added using the operation keys.
For details, refer to page 19.
Note: Advanced functions consist of the dual count calculating mode, output 1 time (for 2-stage counter), decimal point position, prescale value, display
color, output allocation, and key protect level.
MODE
1
Note: The key must be pressed before the key.
MODE
1
Select the configuration using the and keys ( key with 6-digit models).
H7CX-A
19
Settings for All Functions
Note: At the time of delivery, the H7CX is set to the 1-stage counter (2-stage counter for H7CX-AW@/-A4W@ models) configuration. When using
as a 2-stage (or 1-stage) counter, total and preset counter, batch counter, or dual counter, switch to the configuration using the procedure
given on page 36.
(1ms)(20ms)
(30Hz) (5kHz)
(N)
(0.50s) (99.99s)(0.01s)
(0.50s) (99.99s)(0.01s)
(0.01s) (99.99s)
(F) (C) (R) (K-1) (P) (Q) (A) (K-2) (D) (L) (H)
(KP-1) (KP-2) (KP-3) (KP-4) (KP-5)
(99.999) [9.999](1.000)(0.001)
(0.50s) (99.99s)(0.01s)
The characters displayed in reverse video are the default settings.
Power ON
Note 4: Displayed for output modes other than K-2, D, L, and H only.
Input mode
Output mode
Display color
See note 1. See note 2.
For details on operations and display in run mode, refer to page 22.
The display depends on the configuration used.
3 s min. 3 s min.
When using as a 2-stage counter:
(Addition) (Subtraction)
(Outputs held)
See note 7.
See note 3.
See note 6.
See note 5.
See note 4.
See note.
See note 4.
See note 5.See note 5.See note 5.
Note: Displayed for terminal-block models (except H7CX-A11@) only.
(Red) (Green) (Red-green) (Green-red)
Settings that cannot be performed with the DIP switch are performed with the operation keys.
When using as a dual counter:
Note 3:
Note 6:
See note 7.
Note: Displayed for H7CX-AU@ models only.
Run mode
Function setting mode
Note: 1. If the mode is switched to the function setting mode during operation, operation will
continue.
2. Changes made to settings in function setting mode are enabled for the first time when the
mode is changed to run mode. Also, when settings are changed, the counter is reset
(present value initialized and output turned OFF) on returning to run mode.
When performing settings with operation keys only, set pin1 of the DIP switch to OFF (factory setting).
If pin 1 of the DIP switch is set to ON, the setting items indicated by will not be displayed.
Key protect
level
Output
allocation
NPN/PNP
input mode
Prescale
value
Decimal
point
position
Reset input
signal
width
Counting
speed
One-shot
output
time
(UP) (DOWN) (UP/DOWN A) (UP/DOWN B) (UP/DOWN C)
Dual count
calculating mode
Note: Displayed only when the output
mode is K-2, D, L, or H.
Note: 5. Display only when the input mode is UP/DOWN A, B,
or C with 6-digit models (with H7CX-AU@/-AW@
models only for H).
One-
shot
output
2 time
One-
shot
output
1 time
One-
shot
output
2 time
Note: Displayed only when the output mode is C, R, K-1, P,
Q, A, or K-2.
Note: Displayed only when the
output mode is C, R, K-1, P,
Q, A, or K-2.
If the output time is 0.00, hold is
displayed.
Note 1: Displayed for output modes
other than D, L, and H.
Note 2: HOLD cannot be set when the
output mode is K-2.
Note: Displayed only when the output
mode is C, R, K-1, P, Q, A, or K-2.
When using as a
batch counter:
No decimal
point
One digit after
decimal point
Two digits after
decimal point
Three digits after
decimal point
Note 7: The displays for 4-digit models are shown inside
parentheses.
(NPN
input)
(PNP
input)
Set each setting item using the keys. ( key only for 6-digit models)
r
rr
H7CX-A
20
Explanation of Functions
Input Mode (cntm) (Setting possible using DIP switch.)
Set increment mode (UP), decrement mode (DOWN), or one of the
increment/decrement modes (UP/DOWN A, UP/DOWN B, or UP/
DOWN C) as the input mode. Input modes other than UP or DOWN
modes cannot be set using the DIP switch and so use the operation
keys if other modes are required. (For details on the operation of the
input modes, refer to Input Modes and Present Value on page 23.)
Dual Count Calculating Mode (calm)
When using as a dual counter, select either ADD (addition) or SUB
(subtraction) as the calculation method for the dual count value. SUB
mode can be used only when K-2, D, L, or H is selected as the output
mode with 6-digit models.
ADD: Dual count value = CP1 PV + CP2 PV
SUB: Dual count value = CP1 PV CP2 PV
Output Mode (outm) (Setting possible using DIP switch.)
Set the way that control output for the present value is output. The
possible settings are N, F, C, R, K-1, P, Q, A, K-2, D, L, and H. Output
modes other than N, F, C, or K-1 cannot be set using the DIP switch
and so use the operation keys if other modes are required. The out-
put modes that can be set vary with the model. (For details on the
operation of the output modes, refer to Input/Output Mode Settings
on page 24.)
One-shot Output Time (otim) (Setting possible using DIP
switch.)
Set the one-shot output time (0.01 to 99.99 s) for control output.
One-shot output can be used only when C, R, K-1, P, Q, A, or K-2 is
selected as the output mode. Output times other than 0.5 s or 0.05 s
cannot be set with the DIP switch and so use the operation keys if
other settings are required.
One-shot Output 2 Time (otm2) (Setting possible using
DIP switch.)
When using as a 2-stage counter or batch counter, set the one-shot
output time (0.01 to 99.99 s) for control output (OUT2). One-shot out-
put can be used only when C, R, K-1, P, Q, A, or K-2 is selected as
the output mode. Output times other than 0.5 s or 0.05 s cannot be
set with the DIP switch and so use the operation keys if other settings
are required.
One-shot Output 1 Time (otm1)
When using as a 2-stage counter, set the one-shot output time (0.01
to 99.99 s) for control output (OUT1). One-shot output can be used
only when D, L, or H is selected as the output mode. If the output
time is set to 0.00, hold is displayed, and outputs are held. HOLD
cannot be set when the output mode is K-2.
Counting Speed (cnts) (Setting possible using DIP
switch.)
Set the maximum counting speed (30 Hz/5 kHz) for CP1 and CP2
inputs together. If contacts are used for input signals, set the count-
ing speed to 30 Hz. Processing to eliminate chattering is performed
for this setting.
Reset Input Signal Width (iflt) (Setting possible using
DIP switch.)
Set the reset input signal width (20 ms/1 ms) for reset/reset 1 and
total reset/reset 2 inputs together. If contacts are used for input sig-
nals, set the counting speed to 20 ms. Processing to eliminate chat-
tering is performed for this setting.
Decimal Point Position (dp)
Decide the decimal point position for the present value, CP1/CP2
present values, set value (SV1, SV2), total count value, and dual
count set value.
Prescale Value (pscl)
Pulses input to the counter are converted according to the specified
prescale value. (Setting range: 0.001 to 99.999 for 6-digit models
and 0.001 to 9.999 for 4-digit models.)
Example: To display the feed distance for systems that output
25 pulses for a feed length of 0.5 m in the form @@.@@ m:
1. Set the decimal point position to 2 decimal places.
2. Set the prescale value to 0.02 (0.5÷25).
NPN/PNP Input Mode (imod)
Select either NPN input (no-voltage input) or PNP input (voltage
input) as the input format. The same setting is used for all external
inputs. For details on input connections, refer to Input Connections
on page 11.
Display Color (colr)
Set the color used for the present value.
Note: When using as a 2-stage counter, this is the status of output 2.
Output Allocation (otst)
When using H7CX-AU@ models as a 2-stage counter, the output can
be flexibly allocated to either stage 1 or 2.
Transistor output can be allocated to SV1 and contact output for SV2
or vice verse, as in the following table.
H7CX-AU/-AUD1
H7CX-AUSD1
Output OFF (See note.) Output ON (See note.)
red Red (fixed)
grn Green (fixed)
r-g Red Green
g-r Green Red
OUT1 OUT2
off Transistor (12-13) Contact (3, 4, 5)
on Contact (3, 4, 5) Transistor (12-13)
OUT1 OUT2
off Transistor (12-13) Transistor with diode
(3, 4, 5)
on Transistor with diode
(3, 4, 5)
Transistor (12-13)
0.5 m
Encoder
25 pulses
H7CX-A
21
Key Protect Level (kypt)
Set the key protect level.
When the key-protect switch is set to ON, it is possible to prevent setting errors by prohibiting the use of certain operation keys by specifying the
key protect level (KP-1 to KP-5). The key protect indicator is lit while the key-protect switch is set to ON. Confirm the ON/OFF status of the key-
protect switch after the H7CX is mounted to the panel.
Note: Changing mode to configuration selection mode ( + 1 s min.) or function setting mode ( 3 s min.).
ON
OFF
Note: Factory-set to OFF
Key protect indicator
(See note)
Level Meaning Details
Changing mode
(See note.)
Switching display in
run mode
Reset key Up/down key (Up key for
6-digit models)
KP-1 (default setting) No Yes Yes Yes
KP-2 No Yes No Yes
KP-3 No Yes Yes No
KP-4 No Yes No No
KP-5 No No No No
MODE 1MODE
H7CX-A
22
Operation in Run Mode
1-stage Counter
2-stage Counter
Total and Preset Counter
Batch Counter
Dual Counter
CP2 present value
CP1 present value
Dual count set value
Dual count value
Batch count set value
Present value
Batch count value
Set value
Present value
Total count value
Set value
Present value
Present value
Set value 2
Set value 1
Present value
Set value
Present Value
Shows the present count value.
Set Value (Set Value 1, Set Value 2)
Present Value/Set Value
Same as 1-stage counter.
Total Count Value
Shows the present total count value.
Present Value/Set Value
Same as 1-stage counter.
Batch Count Value
Batch Count Set Value
Dual Count Value
Dual Count Set Value
CP1/CP2 Present Value
Show the present count values for CP1 and CP2 present values respectively.
Set values for each digit as required using the and keys. ( key only for 6-digit models.)
Set the set value. When the present
value reaches the set value, signals
are output according to the specified
output mode.
Shows the number of times the count has
been completed for the present value.
Set the batch count set value. When the
batch count value reaches the batch count
set value, batch output (OUT1) turns ON.
Shows the sum of the CP1 present value and CP2 present value when the
dual count calculating mode is ADD and shows the value obtained by
subtracting the CP2 present value from the CP1 present value when the dual
count calculating mode is SUB.
Set the dual count set value. When the dual count value reaches the dual
count set value, signals are output according to the specified output mode.
H7CX-A
23
Input Modes and Present Value
Note: 1. If the configuration selection is set to dual counter, CP1 and
CP2 input will operate in the same way as the count input
(CP1) of UP (increment) mode.
2. a must be greater than the minimum signal width and b
must be at least 1/2 the minimum signal width. If they are
less, a count error of ±1 may occur.
Minimum signal width:16.7 ms (when maximum counting
speed = 30 Hz)
100 µs (when maximum counting
speed = 5 kHz)
3. Counting starts when the CP1 is turned ON after turning ON
the power.
4. The meaning of the H and L symbols in the tables is ex-
plained below.
UP (Increment) Mode DOWN (Decrement) Mode
0
CP1
H
L
CP2
H
L
0
1
2
4
3
5
A A
CP1: Count input; CP2: Prohibit (gate) input
Present
value
a must be greater than the minimum signal width. (See note 2.)
Prohibit
n
CP1
H
L
CP2
H
L
0
n1
n2
n4
n3
n5
A A
Prohibit
a must be greater than the minimum signal width. (See note 2.)
CP1: Count input; CP2: Prohibit (gate) input
Present
value
0
CP1
H
L
CP2
H
L
0
1
2
4
3
5
A A
Prohibit
a must be greater than the minimum signal width. (See note 2.)
CP1: Prohibit (gate) input; CP2: Count input
Present
value
(See note 3.)
n
CP1
H
L
CP2
H
L
0
n1
n2
n4
n3
n5
A A
Prohibit
a must be greater than the minimum signal width. (See note 2.)
CP1: Prohibit (gate) input; CP2: Count input
Present
value
(See note 3.)
UP/DOWN A
Command Input Mode
UP/DOWN B
Individual Input Mode
UP/DOWN C
Quadrature Input Mode
0
CP1
H
L
CP2
H
L
0
1
22
2
1
33
A A
a must be greater than the minimum signal width. (See note 2.)
Present
value
0
CP1
H
L
CP2
H
L
0
1
222
11
33
Present
value
0
CP1
H
L
CP2 H
L
0
1
22
2
1
33
B B B B
b must be at least 1/2 the minimum signal width. (See note 2.)
Present
value
Input method
Symbol
No-voltage input
(NPN input)
Voltage input
(PNP input)
HShort-circuit 4.5 to 30 VDC
LOpen 0 to 2 VDC
H7CX-A
24
Input/Output Mode Settings
Operation for 1-stage models is the same as that for OUT2.
When using a 2-stage model as a 1-stage counter, total and preset
counter, or dual counter, OUT1 and OUT2 turn ON and OFF simulta-
neously.
Note: 1. The full scale (FS) for H7CX 4-digit models is 9999.
2. When the present value reaches 999999, it returns to 0.
3. Counting cannot be performed during reset/reset 1 input.
4. If reset/reset 1 is input while one-shot output is ON, one-shot output turns OFF.
5. If there is power failure while output is ON, output will turn ON again when the power supply has recovered. For one-shot output, output
will turn ON again for the duration of the output time setting once the power supply has recovered.
6. Do not use the counter function in applications where the count may be completed (again) while one-shot output is ON.
One-shot output from OUT1
Self-holding output Self-holding output One-shot output from OUT2
(The one-shot output time
can be set in the range 0.01
to 99.99s.)
Input mode Operation after count
completion
UP DOWN UP/DOWN A, B, C
Output
mode
setting
NThe outputs and
present value display
are held until reset/re-
set 1 is input.
FThe present value dis-
play continues to in-
crease/decrease. The
outputs are held until
reset/reset 1 is input.
CAs soon as the count
reaches SV, the present
value display returns to
the reset start status.
The present value dis-
play does not show the
present value upon
count-up.
The outputs repeat
one-shot operation.
OUT1 self-holding out-
put turns OFF after the
OUT2 one-shot output
time.The OUT1 one-
shot output time is inde-
pendent of OUT2.
RThe present value dis-
play returns to the reset
start status after the
one-shot output time.
The outputs repeat
one-shot operation.
OUT1 self-holding out-
put turns OFF after the
OUT2 one-shot output
time.The OUT1 one-
shot output time is inde-
pendent of OUT2.
999999
0
OUT1
OUT2
Reset/
reset 1
Set
value 2
Set
value 1
999999
0
OUT1
OUT2
Reset/
reset 1
Set
value 2
Set
value 1
999999
0
OUT1
OUT2
Reset/
reset 1
Set
value 2
Set
value 1
999999
0
OUT1
OUT2
Reset/
reset 1
Set
value 2
Set
value 1
H7CX-A
25
Note: 1. The full scale (FS) for H7CX 4-digit models is 9999.
2. When the present value reaches 999999, it returns to 0.
3. Counting cannot be performed during reset/reset 1 input.
4. If reset/reset 1 is input while one-shot output is ON, one-shot output turns OFF.
5. If there is power failure while output is ON, output will turn ON again when the power supply has recovered. For one-shot output, output
will turn ON again for the duration of the output time setting once the power supply has recovered.
6. Do not use the counter function in applications where the count may be completed (again) while one-shot output is ON.
Input mode Operation after
count completion
UP DOWN UP/DOWN A, B, C
Output
mode
setting
K-1 The present value dis-
play continues to in-
crease/decrease.
OUT1 self-holding
output turns OFF after
the OUT2 one-shot
output time.The
OUT1 one-shot out-
put time is indepen-
dent of OUT2.
PThe present value dis-
play does not change
during the one-shot
output time period,
but the actual count
returns to the reset
start status.
The outputs return to
the one-shot start
state and repeat one-
shot operation.
OUT1 self-holding
output turns OFF after
the OUT2 one-shot
output time. The
OUT1 one-shot out-
put time is indepen-
dent of OUT2.
QThe present value
continues to increase/
decrease for the one-
shot output time, but
returns to the reset
start status after the
one-shot output time
has elapsed.
The outputs repeat
one-shot operation.
OUT1 self-holding
output turns OFF after
the OUT2 one-shot
output time. The
OUT1 one-shot out-
put time is indepen-
dent of OUT2.
AThe present value dis-
play and OUT1 self-
holding output is held
until reset/reset 1 is
input. OUT1 and
OUT2 are indepen-
dent.
999999
0
OUT1
OUT2
Reset/
reset 1
Set
value 2
Set
value 1
999999
0
OUT1
OUT2
Reset/
reset 1
Set
value 2
Set
value 1
999999
0
OUT1
OUT2
Reset/
reset 1
Set
value 2
Set
value 1
999999
0
OUT1
OUT2
Reset/
reset 1
Set
value 2
Set
value 1
H7CX-A
26
Applicable Counters
K-2 mode: H7CX-A11@, H7CX-A@, and H7CX-AW@
D mode: H7CX-A11@, H7CX-A@, and H7CX-AW@
L mode: H7CX-A11@, H7CX-A@, and H7CX-AW@
H mode: H7CX-AW@
Note: 1. Counting cannot be performed during reset/reset 1 input.
2. If reset/reset 1 is input while one-shot output is ON, one-shot output turns OFF.
3. If there is power failure while output is ON, output will turn ON again when the power supply has recovered. For one-shot output, output
will turn ON again for the duration of the output time setting once the power supply has recovered.
4. Do not use the counter function in applications where the count may be completed (again) while one-shot output is ON.
Input mode Operation after count
completion
UP/DOWN A, B, C
Output
mode
setting
K-2 The display continues to in-
crease/decrease until the over-
flow or underflow value is
reached. One-shot output only.
DThe display continues to in-
crease/decrease until the over-
flow or underflow value is
reached. The outputs are ON
while the count is equal.
LThe display continues to in-
crease/decrease until the over-
flow or underflow value is
reached.
OUT1 is held while the present
value is less than or equal to set
value 1. OUT2 is held while the
present value is greater than or
equal to set value 2.
HThe display continues to in-
crease/decrease until the over-
flow or underflow value is
reached.
OUT1 is held while the present
value is greater than or equal to
set value 1. OUT2 is held while
the present value is greater than
or equal to set value 2.
Note:
H mode is available only when
using a 6-digit model as a 2-
stage counter.
(The one-shot output time
can be set in the range 0.01
to 99.99s.)
Self-holding
output
Instantaneous
(equals) output
One-shot
output
0
999999
99999
OUT1
OUT2
Reset/
reset 1
Set
value 2
Set
value 1
0
999999
99999
OUT1
OUT2
Reset/
reset 1
Set
value 2
Set
value 1
0
999999
99999
OUT1
OUT2
Reset/
reset 1
Set
value 2
Set
value 1
0
999999
99999
OUT1
OUT2
Reset/
reset 1
Set
value 2
Set
value 1
H7CX-A
27
Total and Preset Counter Operation
The H7CX has a total counter, separate from the 1-stage preset counter, for counting the total accumulated value.
Batch Counter Operation
The H7CX has a batch counter, separate from the 1-stage preset counter, for counting the number of times the count has been completed.
Note: 1. The batch count value is held at 0 during batch counter reset input.
2. If the batch count set value is 0, batch count will be performed but there will be no batch output.
3. The batch count value returns to 0 when it reaches 999,999 (9,999 for 4-digit models).
4. Once batch input has been turned ON, it will return to the ON state after power interruptions.
5. If the batch count set value is changed from a value that is greater than the batch count value to one that is less, batch output will turn ON.
6. After batch output turns ON, the ON state will be held even if the batch count set value is changed to a value greater than the batch count
value.
The total counter continues to count the
total accumulated value when the present
value is reset using reset/reset 1 input
(reset key).
The total count value is reset when the
total reset/reset 2 input is turned ON. If the
reset key is pressed while the total count
value is displayed, the total count value is
reset. The present value is also reset at
this time.
The counting range of the total counter is
99,999 to 999,999 (999 to 9,999). The
total count value returns to 0 when it
reaches the full scale limit.
0
0
999999
Reset/reset 1
Total reset/reset 2
Present value
Total count value
Note: The full scale (FS) for H7CX 4-digit models is 9999.
The batch counter continues after count
completion.
Batch output is held until batch counter
reset is input.
When the batch counter reset input is
turned ON, the batch count value is reset,
and batch output turns OFF.
If the reset key is pressed while the batch
count value is displayed, the batch count
value is reset and batch output turns OFF.
The present value is also reset at this time.
Although the count value can be incre-
mented and decremented, the batch count
is only incremented.
0
0
Reset 1
Reset 2 (batch
counter reset)
Set value
Present value
OUT2
Batch count set value
(Sub-display)
Batch count value
(Main display)
OUT1 (batch output)
Note: The above is for when the output mode is C.
12
H7CX-A
28
Dual Counter Operation
Using the dual counter allows the count from 2 inputs to be added or subtracted and the result displayed. It is possible to specify a set value for
which output turns ON when the set value matches the added or subtracted result.
OUT1 and OUT2 turn ON and OFF simultaneously.
Note: 1. Counting is not possible for CP1 during reset 1 input. CP2 will not be affected. The dual count value will be calculated based on a CP1
present value of 0.
2. Counting is not possible for CP2 during reset 2 input. CP1 will not be affected. The dual count value will be calculated based on a CP2
present value of 0.
3. The counting range for the dual count value is 99,999 to 999,999 (0 to 9,999 for 4-digit models). The counting ranges for the CP1 present
value and CP2 present value are 0 to 999,999 (0 to 9,999 for 4-digit models). If a present value exceeds 999,999 (9,999 for 4-digit mod-
els), FFFFFF (FFFF for 4-digit models) will be displayed to indicate an overflow, and all counting will stop.
The operation after count com-
pletion for the dual counter
value is determined by the out-
put mode.
The CP1 present value is reset
when reset 1 input is turned
ON and the CP2 present value
is reset when reset 2 input is
turned ON.
If the reset key is pressed while
the dual count value, CP1
present value, or CP2 present
value is displayed, all of the
present values are reset and
outputs turn OFF. At this time,
counting is not possible for
CP1 or CP2 inputs.
0
0
0
0
0
0
Dual count value
CP1 present value
CP2 present value
OUT1, 2
Dual count value
Dual count set value
CP1 present value
CP2 present value
OUT1, 2
Note: The above is for when the output mode is N.
Dual Count Calculating Mode = ADD
Dual count value = CP1 PV + CP2 PV
Dual Count Calculating Mode = SUB
Dual count value = CP1 PV CP2 PV
Reset 1
(CP1 reset)
Reset 2
(CP2 reset)
Reset 1
(CP1 reset)
Reset 2
(CP2 reset)
Dual count set value
Note: The above is for when the output mode is
K-2. SUB mode can be used only when
K-2, D, L, or H is selected as the output
mode with 6-digit models.
H7CX-A
29
Reset Function List
Self-diagnostic Function
The following displays will appear if an error occurs.
Note: 1. The display for 4-digit models is given in parentheses.
2. Display flashes (1-second cycles).
3. Occurs when the present value or the total count value goes below 99,999 (999 with 4-digit models).
4. Occurs when the present value reaches 999,999 (9,999 with 4-digit models) under the following conditions:
The output mode is K-2, D, L, or H.
The H7CX is set for dual counter operation.
5. Includes the case where the EEPROM has reached its overwrite lifetime.
Function 1-stage/2-stage
counter
Total and preset counter Batch counter Dual counter
Screen dis-
played in run
mode
Present value/
set value (1, 2)
Present value/
set value
Total count
value
Present value/
set value
Batch count
value/batch
count set value
Dual count
value/dual
count set value
CP1 present
value/CP2
present value
Reset/reset 1 Present value
and output reset.
Present value and output reset. Present value and output reset. Only the CP1 present value is re-
set.
Total reset/re-
set 2
No effect. Only the total count value is reset. Batch count value and batch output
reset.
Only the CP2 present value is re-
set.
Reset key Present value
and output reset.
Present value
and output reset.
Present value,
total count value,
and output reset.
Present value
and output reset.
Present value,
batch count val-
ue, output and
batch output re-
set.
CP1 present value, CP2 present
value, dual count value, and output
reset.
Main display Sub-display Error Output status Correction method Set value after
reset
------
(----)
(See notes 1 and
2.)
No change Present value underflow
(See note 3.)
No change Either press the reset key or turn ON
reset input.
No change
ffffff
(ffff)
(See notes 1 and
2.)
No change Present value overflow
(See note 4.)
No change Either press the reset key or turn ON
reset input.
No change
e1 Not lit CPU OFF Either press the reset key or reset the
power supply.
No change
e2 Not lit Memory error (RAM) OFF Reset the power supply. No change
e2 sum Memory error (EEP)
(See note 5.)
OFF Reset to the factory settings using the
reset key.
0
H7CX-A
30
Operating Procedures (Tachometer Function)
Switching from Counter to Tachometer
Settings for Basic Operations
Easy Confirmation of Switch Settings Using Indicators
The ON/OFF status of the DIP switch pins can be
confirmed using the front display. For details, refer to page 36.
Note: 1. Be sure to set pin 1 of the DIP switch to ON. If it is set to OFF, the DIP switch settings will not be enabled.
2. Changes to DIP switch settings are enabled when the power is turned ON.
Power ON
Configuration selection mode Run mode
+
MODE 1
Switch to 2cnt to taco (tachometer operation) using the key.
The H7CX is factory-set to the 2-stage
counter (1-stage counter for H7CX-AU@
models) configuration. To switch to the
tachometer configuration, use the
procedure shown on the right. For details,
refer to page 36.
Hold down for
1 s min. (See note.)
Note: The key must be pressed before the key.
MODE
1
12345678
Settings for basic functions can be performed with just the DIP switch.
Be sure to set pin 1 to ON.
Note: All of the pins are factory-set to OFF.
ON
OFF
Item OFF ON
1 DIP switch set-
tings enable/
disable
Disabled Enabled
2 Counting speed 30 Hz 10 kHz
3 Tachometer out-
put mode
Refer to the table on the right.
4
5 Average pro-
cessing
Refer to the table on the right.
6
7 Not used --- ---
8 NPN/PNP input
mode
NPN PNP
Pin 3 Pin 4 Tachometer output mode
OFF OFF Upper and lower limit
ON OFF Area
OFF ON Upper limit
ON ON Lower limit
Pin 5 Pin 6 Average processing
OFF OFF OFF (no average processing)
ON OFF 2 times
OFF ON 4 times
ON ON 8 times
Advanced-Function Settings
After making DIP switch settings for basic operations, advanced-functions (see note) can be added using the operation keys.
For details, refer to page 31.
Note: Advanced functions consist of decimal point position, prescale value, auto-zero time, startup time, display color, output
allocation, and key protect level.
H7CX-A
31
Settings for Advanced Functions
Note: When using as a tachometer, switch to the tachometer configuration using the procedure given on page 36.
(30 Hz) (10k Hz)
(99.9s)(0.0s)
(99.9s)(0.1s)
(99.999)(1.000)(0.001)
(KP-1) (KP-2) (KP-3) (KP-4) (KP-5)
Set each setting item using the keys.
(See note 2.)(See note 1.)
3s min. 3s min.
Power ON
The characters displayed in reverse video are the initial values.
For details on operations in run mode, refer to page 34.
Settings that cannot be performed with the DIP switch are performed with the operation keys.
(HI-LO) (LO-LO)(AREA) (HI-HI)
(Red) (Green) (Red-green) (Green-red)
Note: Displayed for H7CX-AU@ models
Run mode
Function setting mode
Note: 1. If the mode is switched to the function setting mode during operation, operation will
continue.
2. Changes made to settings in function setting mode are enabled for the first time when
the mode is changed to run mode. Also, when settings are changed, the counter is
reset (measured values initialized and output turned OFF) on returning to run mode.
When performing settings with operation keys only, set pin1 of the DIP switch to OFF (factory setting). If
pin 1 of the DIP switch is set to ON, the setting items indicated by will not be displayed.
Tachometer
output
mode
Key protect
level
Output
allocation
Display
color
NPN/PNP
input mode
Startup
time
Auto-zero
time
Average
processing
Prescale
value
Decimal
point
position
Counting
speed
(No decimal
point)
(One digit
after decimal
point)
(Two digits
after decimal
point)
(Three digits
after decimal
point)
(No average
processing)
(Average
of 2
measure-
ments)
(Average
of 4
measure-
ments)
(Average
of 8
measure-
ments)
(NPN
input)
(PNP
input)
H7CX-A
32
Explanation of Functions
Tachometer Output Mode (totm) (Setting possible using
DIP switch.)
Set the output method for control output based on the OUT1/OUT2
set value. Upper and lower limit (HI-LO), area (AREA), upper limit
(HI-HI), and lower limit (LO-LO) can be set. (For details on the opera-
tion of the output modes, refer to Output Mode Settings on page 35.)
Counting Speed (cnts) (Setting possible using DIP
switch.)
Set the maximum counting speed (30 Hz/10 kHz) for CP1 input. If
contacts are used for input signals, set the counting speed to 30 Hz.
Processing to eliminate chattering is performed for this setting.
Decimal Point Position (dp)
Decide the decimal point position for the measurement value, OUT1
set value, and OUT2 set value.
Prescale Value (pscl)
It is possible to display the rate of rotation or the speed of a device or
machine to which the H7CX is mounted by converting input pulses to
a desired unit. If this prescaling function is not used, the input fre-
quency (Hz) will be displayed.
The relationship between display and input is determined by the fol-
lowing equation. Set the prescale value according to the unit to be
displayed.
Displayed value = f × a
f: Input pulse frequency (number of pulses in 1 second)
a: Prescale value
1. Displaying Rotation Rate
N: Number of pulses per revolution
Example:In order to display the rate of rotation for a machine that
outputs 5 pulses per revolution in the form @@.@rpm:
1. Set the decimal point position to 1 decimal place.
2. Using the formula, set the prescale value to 1/N × 60 =
60/5 = 12.
2. Displaying Speed
N: Number of pulses per revolution
d: Diameter of rotating body (m)
πd: Circumference (m)
Average Processing (aug) (Setting possible using DIP
switch.)
Flickering display and output chattering can be prevented using aver-
age processing (simple averaging). Average processing can be set to
one of four levels: no average processing, 2 times (i.e., the average
of 2 measurement values), 4 times, or 8 times. The measurement
cycle will be equal to the sampling cycle (200 ms) multiplied by the
average processing setting (i.e., the number of times). Average pro-
cessing enables fluctuating input signals to be displayed stably. Set
the optimum number of times for the application.
Auto-zero Time (aut=)
It is possible to set the H7CX so that if there is no pulse for a certain
time the display is force-set to 0. This time is called the auto-zero
time.
Note: Set the auto-zero time to a time slightly longer than the estimat-
ed interval between input pulses and within the setting range
(0.1 to 99.9 s). It will not be possible to make accurate mea-
surements if the auto-zero time is set to a time shorter than the
input pulse cycle. Setting a time that is too long may also result
in problems, such as a time-lag between rotation stopping and
the alarm turning ON.
Startup Time (stmr)
In order to prevent undesired output resulting from unstable input
immediately after the power supply is turned ON, it is possible to pro-
hibit measurement for a set time (0.0 to 99.9 s), the startup time. It
can also be used to stop measurement and disable output until the
rotating body reaches the normal rate of rotation, after the power
supply to the H7CX and rotating body are turned ON at the same
time.
NPN/PNP Input Mode (imod)
Select either NPN input (no-voltage input) or PNP input (voltage
input) as the input format. The same setting is used for all external
inputs. For details on input connections, refer to Input Connections
on page 11.
Display Color (colr)
Set the color used for the measurement value.
Note: 1. If the tachometer output mode is set to AREA, however, the
measured value is displayed in red when control output 1 is
OFF and in green when control output 1 is ON.
2. If the tachometer output mode is set to AREA, however, the
measured value is displayed in green when control output 1
is OFF and in red when control output 1 is ON.
Display unit Prescale value (a)
rpm 1/N × 60
rps 1/N
Display unit Prescale value (a)
m/min πd × 1/N × 60
m/s πd × 1/N
d: Diameter of
rotating body
Setting Control output OFF Control output ON
red Red (fixed)
grn Green (fixed)
r-g
(See note
1.)
Measured value displayed
in red when both control
outputs 1 and 2 are OFF.
Measured value displayed
in green when either control
output 1 or control output 2
is ON.
g-r
(See note
2.)
Measured value displayed
in green when both control
outputs 1 and 2 are OFF.
Measured value displayed
in red when either control
output 1 or control output 2
is ON.
Startup time
Display
Power supply
Time
Output
(lower limit)
Comparison
value
(lower limit)
H7CX-A
33
Output Allocation (otst)
When using H7CX-AU@ models as 2-stage counter, each output can
be flexibly allocated to either stage 1 or 2.
Transistor output placed for SV1 and contact output for SV2 or vice
verse, as in the following table.
H7CX-AU/-AUD1
H7CX-AUSD1
Key Protect Level (kypt)
Set the key protect level.
When the key-protect switch is set to ON, it is possible to prevent setting errors by prohibiting the use of certain operation keys by specifying the
key protect level (KP-1 to KP-5). The key protect indicator is lit while the key-protect switch is set to ON. Confirm the ON/OFF status of the key-
protect switch after the H7CX is mounted to the panel.
Note: Changing mode to configuration selection mode ( + 1 s min.) or function setting mode ( 3 s min.).
OUT1 OUT2
off Transistor (12-13) Contact (3, 4, 5)
on Contact (3, 4, 5) Transistor (12-13)
OUT1 OUT2
off Transistor (12-13) Transistor with diode
(3, 4, 5)
on Transistor with diode
(3, 4, 5)
Transistor (12-13)
ON
OFF
Note: Factory-set to OFF
Key protect indicator
(See note)
Level Meaning Details
Changing mode
(See note.)
Switching display
during operation
Reset key Up/down key (Up key for
6-digit models)
KP-1 (default setting) No Yes Yes Yes
KP-2 No Yes No Yes
KP-3 No Yes Yes No
KP-4 No Yes No No
KP-5 No No No No
MODE 1MODE
H7CX-A
34
Operation in Run Mode
Self-diagnostic Function
The following displays will appear if an error occurs.
Note: 1. Includes the case where the EEPROM has reached its overwrite lifetime.
2. Occurs when the measurement value reaches 999,999.
3. Display flashes (1-second cycles).
Set values for each digit as required using the key.
Measurement value
Measurement value
OUT1 set value
Measurement value
OUT2 set value
Measurement Value
Displays the currently measured value.
OUT1/OUT2 Set Value
Set OUT1 set value and OUT2 set value. The
measurement value is compared to OUT1 set value
and OUT2 set value and output is made according to
the selected output mode.
Main display Sub-display Error Output status Correction method Set value after
reset
ffffff
(See note 3.)
No change Measurement value overflow
(See note 2.)
No change Measurement value 999999 No change
e1 Not lit CPU OFF Either press the reset key or reset the
power supply.
No change
e2 Not lit Memory error (RAM) OFF Reset the power supply. No change
e2 sum Memory error (EEP)
(See note 1.)
OFF Reset to the factory settings using the
reset key.
0
H7CX-A
35
Output Mode Settings
Output
mode
setting
Upper
and
lower
limit
(HI-LO)
Area
(AREA)
Condition OUT1 set value OUT2 set value OUT1 set value > OUT2 set value
ON
condition
for OUT1
OUT1 set value measurement value OUT2 set
value
OUT2 set value measurement value OUT1 set
value
ON
condition
for OUT2
measurement value < OUT1 set value
or
measurement value > OUT2 set value
measurement value < OUT2 set value
or
measurement value > OUT1 set value
Upper
limit
(HI-HI)
Lower
limit
(LO-LO)
OUT1
OUT2
(Lower-limit) OUT1 set value
(Upper-limit) OUT2 set value
Measurement value
ON condition for OUT1: measurement value OUT1 set value
ON condition for OUT2: measurement value OUT2 set value
OUT1
OUT2
OUT1 set value
OUT2 set value
Measurement value
OUT1
OUT2
(Upper-limit) OUT1 set value
(Upper-limit) OUT2 set value
Measurement value
ON condition for OUT1: Measurement value OUT1 set value
ON condition for OUT2: Measurement value OUT2 set value
OUT1
OUT2
(Lower-limit) OUT1 set value
(Lower-limit) OUT2 set value
Measurement value
ON condition for OUT1: Measurement value OUT1 set value
ON condition for OUT2: Measurement value OUT2 set value
H7CX-A
36
Operation in Configuration Selection Mode
Select which H7CX configuration is used (i.e., 1-stage counter, 2-stage counter, total and preset counter, batch counter, dual counter, or tachom-
eter) in configuration selection mode. The H7CX is also equipped with a DIP switch monitor function, a convenient function that enables the settings
of the DIP switch pins to be confirmed using the front display.
Note: 1. When the mode is changed to configuration selection mode, the present value is reset, outputs turns OFF, and counting (measuring)
stops.
2. Setting changes made in configuration selection mode are enabled when the mode is changed to run mode. If the configuration is
changed, the set value (or set value 1 and set value 2), OUT1 set value or OUT2 set value are initialized.
1
+
12345678
1
1
Indicates that DIP switch pin 8 is ON.
Indicates that DIP switch pin 7 is OFF.
Indicates that DIP switch pin 6 is ON.
Indicates that DIP switch pin 5 is OFF.
Indicates that DIP switch pin 4 is ON.
Indicates that DIP switch pin 3 is OFF.
Indicates that DIP switch pin 2 is ON.
Indicates that DIP switch pin 1 is ON.
Example
The configuration that can be selected depend on the model.
Run ModeConfiguration Selection Mode
Counting stopped
Counting possible
Power ON
1 s min.
(See note 2.) (See note 1.)
1
1
To change the mode to configuration selection mode, press
the Key for 1 s min. with the key held down. The
mode will not change if the key is pressed first.
Select the configuration using the keys. ( key only for 6-digit
models)
The H7CX is factory-set to the 1-stage counter configuration (2-stage
counter configuration with H7CX-AW@/-A4W@ models).
Configuration
selection
DIP switch
monitor
(1-stage counter) (2-stage counter) (Dual counter)(Batch counter) (Tachometer)
(Total and preset
counter)
The status of the DIP switch pins (1 to 8) can be confirmed using the
keys.
Note: This display is possible only if DIP switch pin 1 (DIP switch
settings) is set to ON (i.e., enabled).
ON
OFF
H7CX-A
37
Additional Information
Key Operation Flowchart
Counter Operation
Note: 1. Perform settings using the and keys ( key only with 6-digit models).
2. The above flowcharts outline the procedures for all models. For more details on each model, refer to page 19.
1
+
1
+
Configuration selection mode
3 s min.
3 s min.
Configuration selection
DIP switch monitor
Input mode
Function setting mode
Counting stopped
Counting possible
Dual count calculating mode
Output mode
One-shot output time
One-shot output 2 time
One-shot output 1 time
Counting speed
Reset input signal width
Decimal point position
Prescale value
NPN/PNP input mode
Display color
Key protect level
Output allocation
1 s min.
1 s min.
Power ON
Run mode
1-stage counter
Present value, set value
2-stage counter
Present value, set value 1
Present value, set value 2
Total and preset counter
Present value, set value
Total count value
Batch counter
Present value, set value
Dual counter
Batch count value,
batch count set value
Dual count value,
dual count set value
CP1 present value,
CP2 present value
H7CX-A
38
Tachometer Operation
Note: 1. All setting changes are performed using the key.
2. For details, refer to page 31.
1
+
1
+
Power ON
Run mode
1 s min.
1 s min.
3 s min.
3 s min.
Measurement value Tachometer output mode
Counting speed
Decimal point position
Prescale value
Average processing
Auto-zero time
Startup time
NPN/PNP input mode
Display color
Key protect level
Configuration selection mode
Configuration selection
DIP switch monitor
Counting stopped
Counting possible
Function setting mode
Output allocation
Measurement value,
OUT1 set value
Measurement value,
OUT2 set value
H7CX-A
39
Lists of Settings
Fill in your set values in the set value column of the following tables and utilize the tables for quick reference.
Configuration Selection Mode
Note: 1. The setting range varies with the model.
2. The default value for H7CX-AW@/-A4W@ models is 2cnt.
Settings for Counter Operation
Run Mode
1-stage Counter
2-stage Counter
Total and Preset Counter
•Batch Counter
Parameter
name
Parameter Setting range Default value Unit Set value
Configuration
selection
func 1cnt/2cnt/tcnt/bcnt/dcnt/taco (See note 1.) 1cnt
(See note 2.)
---
DIP switch
monitor
dip on/off off --- ---
Parameter name Parameter Setting range Default value Unit Set value
Present value,
set value
Present value --- -99999 to 999999 (-999 to 9999)0-- ---
Set value --- 0 to 999999 (0 to 9999) (For conditions other
than those described in note 1.)
0---
-99999 to 999999 (-999 to 9999)
(See note 1.)
Parameter name Parameter Setting range Default value Unit Set value
Present value,
set value 1
Present value --- -99999 to 999999 (-999 to 9999)0--- ---
Set value 1 --- 0 to 999999 (0 to 9999) (For conditions other
than those described in note 1.)
0---
-99999 to 999999 (-999 to 9999)
(See note 1.)
0
Present value,
set value 2
Present value --- -99999 to 999999 (-999 to 9999)0--- ---
Set value 2 --- 0 to 999999 (0 to 9999) (For conditions other
than those described in note 1.)
0---
-99999 to 999999 (-999 to 9999)
(See note 1.)
0
Parameter name Parameter Setting range Default value Unit Set value
Present value,
set value
Present value --- -99999 to 999999 (-999 to 9999)0--- ---
Set value --- 0 to 999999 (0 to 9999) (For conditions other
than those described in note 1.)
0---
-99999 to 999999 (-999 to 9999)
(See note 1.)
Total count value --- -99999 to 999999 (-999 to 9999)0--- ---
Parameter name Parameter Setting range Default value Unit Set value
Present value,
set value
Present value --- -99999 to 999999 (-999 to 9999)0--- ---
Set value --- 0 to 999999 (0 to 9999) (For conditions other
than those described in note 1.)
0---
-99999 to 999999 (-999 to 9999)
(See note 1.)
Batch count
value, batch
count set value
Batch count
value
--- 0 to 999999 (0 to 9999)0--- ---
Batch count
set value
--- 0 to 999999 (0 to 9999)0---
H7CX-A
40
•Dual Counter
Note: 1. The input mode is increment/decrement mode and the output mode is K-2, D, L, or H.
2. The dual count calculating mode is subtraction mode and the output mode is K-2, D, L, or H.
Function Setting Mode
Note: 1. The setting range varies with the output mode.
2. The setting range varies with the model and the input mode.
3. HOLD cannot be set when the output mode is K-2.
Parameter name Parameter Setting range Default value Unit Set value
Dual count
value, dual count
set value
Dual count value --- -99999 to 999999 (-999 to 9999)0--- ---
Dual count set
value
--- 0 to 999999 (0 to 9999) (For conditions other
than those described in note 2.)
0---
-99999 to 999999 (-999 to 9999)
(See note 2.)
CP1 present
value, CP2
present value
CP1 present
value
--- 0 to 999999 (0 to 9999)0--- ---
CP2 present
value
--- 0 to 999999 (0 to 9999)0--- ---
Parameter name Parameter Setting range Default value Unit Set value
Input mode cntm up/down/ud-a/ud-b/ud-c (See note 1.) up ---
Dual count calculating
mode
caln add/sub (See note 1.) add ---
Output mode outm n/f/c/r/k-1/p/q/a/k-2/d/l/h (See note 2.) n---
One-shot output time otim 0.01 to 99.99 0.50 s
One-shot output 2 time otm2 0.01 to 99.99 0.50 s
One-shot output 1 time otm1 hold/0.01 to 99.99 (See note 3.) hold s
Counting speed cnts 30h=/skh= 30h= ---
Reset input signal width iflt 20ms/1ms 20ms ---
Decimal point position dp ------/-----.-/----.--/---.---
(----/---.-/--.--/-.---)
------
(----)
Prescale value pscl 0.001 to 99.999 (0.001 to 9.999)1.000 ---
NPN/PNP input mode imod npn/pnp npn ---
Display color colr red/grn/r-g/g-r red ---
Output allocation otst off/on off ---
Key protect level kypt kp-1/kp-2/kp-3/kp-4/kp-5 kp-1 ---
H7CX-A
41
Settings for Tachometer Operation
Run Mode
Function Setting Mode
Parameter name Parameter Setting range Default value Unit Set value
Measurement value --- 0 to 999999 0 --- ---
Measurement
value, OUT1 set
value
Measurement
value
--- 0 to 999999 0 --- ---
OUT1 set value --- 0 to 999999 0 ---
Measurement
value, OUT2 set
value
Measurement
value
--- 0 to 999999 0 --- ---
OUT2 set value --- 0 to 999999 0 ---
Parameter name Parameter Setting range Default value Unit Set value
Tachometer output
mode
totm hold/area/hihi/lolo hilo ---
Counting speed cnts 30h=/10kh= 30h= ---
Decimal point position dp ------/-----.-/----.--/---.--- ------ ---
Prescale value pscl 0.001 to 99.999 1.000 ---
Average processing aUg off/2/4/8off---
Auto-zero time aut= 0.1 to 99.9 99.9 ---
Startup time stmr 0.0 to 99.9 0.0 s
NPN/PNP input mode imod npn/pnp npn s
Display color colr red/grn/r-g/g-r red ---
Output allocation otst off/on off ---
Key protect level kypt kp-1/kp-2/kp-3/kp-4/kp-5 kp-1 ---
42
Tachometer
H7CX-R
DIN 48 × 48 mm Socket-type Tachometer
with a Bright, Easy-to-view, Backlit Negative
Transmissive LCD
Socket design allows either flush or surface mounting.
Operation in any of the four following modes is possible with the
same Unit: Upper and lower limit, upper limit, lower limit, and ar-
ea.
Equipped with auto-zero time, average processing, and startup
time functions.
Contents
Model Number Structure.............................................................. 43
Ordering Information.................................................................... 43
Specifications............................................................................... 44
Connections................................................................................. 46
Nomenclature .............................................................................. 48
Dimensions .................................................................................. 49
Operating Procedures.................................................................. 51
Additional Information .................................................................. 58
H7CX-R
43
Model Number Structure
Model Number Legend
Note: Some configurations are not available.
1. Terminal structure
11: 11-pin socket
2. Supply voltage
None: 100 to 240 VAC, 50/60 Hz
D1: 24 VDC, 50/60 Hz, 12 to 24 VDC
Ordering Information
List of Models
Accessories (Order Separately)
Note: Y92A-48G is a finger-safe terminal cover attached to the P3GA-11 Socket.
12
H7CX-R11@
Sensor power
supply
Output type Supply voltage Tachometer
11-pin socket
12 VDC Contact output 100 to 240 VAC H7CX-R11
24 VAC/12 to 24 VDC H7CX-R11D1
Name Models
Flush Mounting Adapter Y92F-30
Waterproof Packing Y92S-29
Track Mounting/Front Connecting
Socket
11-pin P2CF-11
11-pin, finger-safe type P2CF-11-E
Back Connecting Socket 11-pin P3GA-11
11-pin, finger-safe type P3GA-11 with Y92A-48G (See note.)
Hard Cover Y92A-48
Soft Cover Y92A-48F1
Mounting Track 50 cm (l) × 7.3 mm (t) PFP-50N
1 m (l) × 7.3 mm (t) PFP-100N
1 m (l) × 16 mm (t) PFP-100N2
End Plate PFP-M
Spacer PFP-S
H7CX-R
44
Specifications
Ratings
Note: 1. Permissible ripple: 20% (p-p) max.
2. The display is lit only when the power is ON.
Classification Tachometer
Rated supply voltage (See note 1.) 100 to 240 VAC (50/60 Hz)
24 VAC (50/60 Hz)/12 to 24 VDC
Operating voltage range 85% to 110% of rated supply voltage (90% to 110% at 12 VDC)
Power consumption Approx. 9.4 VA at 264 VAC
Approx. 7.1 VA at 26.4 VAC
Approx. 4.7 W at 12 VDC
Mounting method Flush mounting, surface mounting, or DIN track mounting
External connections 11-pin socket
Display (See note 2.) 7-segment, negative transmissive LCD;
Present value: 9-mm-high characters, red
Comparison value: 6-mm-high characters, green
Digits 6 digits(0 to 999999)
Input signals Count, hold
Input method No-voltage input/voltage input (switchable)
No-voltage input
ON impedance: 1 k max. (Leakage current: 5 to 20 mA at 0 )
ON residual voltage: 3 V max.
OFF impedance: 100 k min.
Voltage input
High (logic) level: 4.5 to 30 VDC
Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 k)
Hold input Minimum input signal width: 20 ms
Pulse measurement method Periodic measurement (Sampling period: 200 ms)
Display refresh cycle
Input pulse of 5 Hz min.: 200 ms
(Using the averaging setting: 200 multiplied by the averaging setting (ms))
Input pulse of less than 5 Hz: Input pulse cycle
(Using the averaging setting: Two times the maximum of the input pulse cycle multiplied by the averaging
setting.)
Max. counting speed 30 Hz or 10 kHz (selectable)
Measuring range 30 Hz: 0.001 Hz to 30.00 Hz
10 kHz: 0.001 Hz to 10 kHz
Measuring accuracy ±0.1% FS ±1 digit max. (at 23 ±5°C)
Output modes HI-LO, AREA, HI, LO
Auto-zero time 0.1 to 999.9 s
Startup time 0.0 to 99.9 s
Average processing OFF/2/4/8 times
Control output Contact output: 3 A at 250 VAC/30 VDC, resistive load (cosφ=1)
Minimum applied load:10 mA at 5 VDC (failure level: P, reference value)
NEMA B300 Pilot Duty, 1/4 HP 3-A resistive load at 120 VAC, 1/3 HP 3-A resistive load at 240 VAC
Output type SPDT
External power supply 12 VDC (±10%), 100 mA Refer to Safety Precautions (Common) on page 59 for details.
Key protection Ye s
Prescaling function 0.001 to 99.999
Decimal point adjustment Rightmost 3 digits
Sensor waiting time 250 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.)
Memory backup EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min.
Ambient temperature Operating: 10 to 55°C (10 to 50°C if tachometers are mounted side by side) (with no icing or conden-
sation)
Storage: 25 to 65°C (with no icing or condensation)
Ambient humidity 25% to 85%
Case color Black (N1.5)
H7CX-R
45
Characteristics
Note: 1. To meet UL listing requirements with the H7CX-R11@ models, an OMRON P2CF-11-@ or P3GA-11 Socket must be mounted on the H7CX. Otherwise,
H7CX-R11@ models are considered to meet UL508 recognition requirements.
2. The Y92S-29 Waterproof Packing and Y92F-30 Flush Mounting Adapter are necessary to ensure IP66, NEMA4, and UL Type 4X waterproofing between the
H7CX and installation panel.
Life-test Curve (Reference Values)
Resistive Load Inductive Load
Reference: A current of 0.15 A max. can be switched at 125 VDC (cosφ=1) and current of 0.1 A max. can be switched if L/R=7 ms. In both cases,
a life of 100,000 operations can be expected. The minimum applicable load is 10 mA at 5 VDC (failure level: P).
Inrush Current (Reference Values)
Item H7CX-R
Insulation resistance 100 M min. (at 500 VDC) between current-carrying terminal and exposed non-current-carrying metal parts, and between non-con-
tinuous contacts
Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-current-carrying metal parts
2,000 VAC (for 100 to 240 VAC), 50/60 Hz for 1 min between power supply and input circuit (1,000 VAC for 24 VAC/12 to 24 VDC)
2,000 VAC 50/60 Hz for 1 min between control output, power supply, and input circuit
1,000 VAC, 50/60 Hz for 1 min between non-continuous contacts
Impulse withstand voltage 3 kV (between power terminals) for 100 to 240 VAC, 1 kV for 24 VAC/12 to 24 VDC
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) for 100 to 240 VAC,
1.5 kV for 24 VAC/12 to 24 VDC
Noise immunity ±1.5 kV (between power terminals)
±600 V (between input terminals)
Square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise)
Static immunity Destruction: 15 kV
Malfunction: 8 kV
Vibration resistance Destruction: 10 to 55 Hz with 0.75-mm single amplitude, each in three directions for 2 hours
Malfunction: 10 to 55 Hz with 0.35-mm single amplitude, each in three directions for 10 min
Shock resistance Destruction: 294 m/s2 each in three directions
Malfunction: 196 m/s2 each in three directions
Life expectancy Mechanical: 10,000,000 operations min.
Electrical: 100,000 operations min. (3 A at 250 VAC, resistive load)
See Life-test Curve (Reference Values) on page 45.
Approved safety standards
(See notes 1 and 2.)
UL508/Listing, UL 50 Type 4X for indoor use (enclosure rating)
CSA C22.2 No. 14, conforms to EN61010-1 (Pollution degree 2/overvoltage category II)
EMC (EMI) EN61326
Emission Enclosure: EN55011 Group 1 class A
Emission AC mains: EN55011 Group 1 class A
(EMS) EN61326
Immunity ESD: EN61000-4-2: 4 kV contact discharge (level 2);
8 kV air discharge (level 3)
Immunity RF-interference: EN61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) (level 3);
10 V/m (Pulse-modulated, 900 MHz ±5 MHz) (level 3)
Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (level 3)
Immunity Burst: EN61000-4-4: 2 kV power-line (level 3);
1 kV I/O signal-line (level 4)
Immunity Surge: EN61000-4-5: 1 kV line to lines (power and output lines) (level 2);
2 kV line to ground (power and output lines) (level 3)
Immunity Voltage Dip/Interruption: EN61000-4-11: 0.5 cycle, 100% (rated voltage)
Degree of protection Panel surface: IP66, NEMA 4 (indoors), and UL Type 4X (indoors) (See note 2.)
Weight Approx. 140 g
1,000
700
500
300
100
70
50
01 2 34
250 VAC (cosφ=1)
Load current (A)
30 VDC (cosφ=1)
No. of operations (×103)
1,000
700
500
300
100
70
50
01 2 34
250 VAC cosφ=0.4
Load current (A)
30 VDC (L/R=7 ms)
No. of operations (×103)
Model Voltage Applied voltage Inrush current (peak value) Time
H7CX-R11 100 to 240 VAC 264 VAC 5.8 A 0.7 ms
H7CX-R11D1 24 VAC/12 to 24 VDC 26.4 VAC 10.4 A 1.2 ms
H7CX-R
46
Connections
Block Diagram
I/O Functions
Note: Refer to page 56 for details on the hold function.
Terminal Arrangement
Note: 1. Terminals 4, 5, and 7 are all for the hold function. The func-
tion is the same whichever terminal is connected. Terminals
4, 5, and 7 are not connected internally and so do not use
them for bridge wiring.
2. Recommended wire: AWG 18 to 24 (Cross-sectional area:
0.205 to 0.823 mm2), solid or twisted, copper or aluminum
Input Circuits
Count and Hold Inputs
No-voltage Inputs (NPN Inputs)
Voltage Inputs (PNP Inputs)
Input circuit
Display circuit
Output circuit
(Basic
insulation) Power supply
circuit
Key switch
circuit
Internal control
circuit
(Basic insulation)(Basic insulation)
Inputs Count Reads counting signals.
Hold Holds the measurement value and outputs.
The hold indicator is lit during hold.
Outputs OUT Outputs signals according to the specified output mode when a comparison value is reached.
67
8
9
10
11
1
2
3
4
5
(+)
()
Count
Hold
0 V
()
(+)
OUT
Hold
Hold
Sensor, etc.
12 VDC
External power supply
Internal circuit
+14 V
1 k
IN Internal
circuit
Approx. 4.7 k
IN Internal
circuit
H7CX-R
47
Input Connections
The inputs of the H7CX-R can be used as either no-voltage (short-circuit or open) inputs or voltage inputs. They are set for use as voltage inputs
at the time of delivery.
No-voltage Inputs (NPN Inputs)
No-voltage Input Signal Levels
Note: The DC voltage must be 30 VDC max.
Applicable Two-wire Sensor
Leakage current: 1.5 mA max.
Switching capacity: 5 mA min.
Residual voltage: 3.0 VDC max.
Operating voltage: 10 VDC
Voltage Inputs (PNP Inputs)
Voltage Input Signal Levels
High level (Input ON): 4.5 to 30 VDC
Low level (Input OFF): 0 to 2 VDC
Input resistance: Approx. 4.7 k
Note: The DC voltage must be 30 VDC max.
0 V 0 V 0 V 0 V
3 54 7 6 3 654 7 3 654 7 3 654 7
Open Collector
Operates when the transistor turns ON.
Voltage Output
Operates when the transistor turns ON.
Contact Input
Operates when the contact turns ON.
PLC or
sensor
Operates when the transistor turns ON.
DC Two-wire Sensor
Sensor
Input
Hold
Count
Input
Hold
Count
Input
Hold
Count
Input
Hold
Count
Terminal
number
Terminal
number
Terminal
number
Terminal
number
No-contact input Short-circuit level (Transistor ON)
Residual voltage: 3 V max.
Impedance when ON: 1 k max.
(The leakage current is approx. 12 mA when
the impedance is 0 .)
Open level (Transistor OFF)
Impedance when OFF: 100 k min.
Contact input Use contact which can adequately switch
5 mA at 10 V.
0 V 0 V 0 V
3 654 7 3 654 7 3 654 7
Sensor
Operates when the transistor turns OFF. Operates when the transistor turns ON.
Contact Input
Operates when the contact turns ON.
Input
Hold
Count
No-contact Input
(NPN Transistor)
No-contact Input
(PNP Transistor)
Sensor
Input
Hold
Count
Input
Hold
Count
Terminal
number
Terminal
number
Terminal
number
H7CX-R
48
Nomenclature
A
B
C
D
G
H
E
F
I
J
K
Indicators Operation Keys
Switches
Key Protection Indicator (Orange)
Lit when the key protect switch is ON.
Comparison Value 1, 2 Stage Indicator
6th digit
Key Protect Switch
DIP Switch
Hold Indicator (Orange)
Lit when the hold input or hold key is
ON.
Control Output Indicator (Orange)
Lit when output is ON.
Present Value (Main Display)
Character height: 9 mm (Red)
Comparison Value (Sub-display)
Character height: 6 mm (Green)
Mode Key
Used to switch mode and setting items.
Hold Key
Used to sustain the measurement value
and output.
Up Keys: 1 to 6
1st digit
(Factory setting)
HLD
HLD
TACHOMETER
1
2
3
7
4
8
6
5
9
10
11
1
OFF
ON
2345678
OFF
(disable)
ON
(enable)
(Factory setting)
H7CX-R
49
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Tachometer (without Flush Mounting Adapter)
Dimensions with Flush Mounting Adapter
(Adapter and Waterproof Packing Ordered Separately)
Dimensions with Front Connecting Socket
Note: These dimensions vary with the kind of DIN track (reference value).
A
45
+0.6
0
45
+0.6
0
0
A = (48n 2.5)+1
Panel Cutouts
60 min.
60 min.
15 min.
n side by side mounting
Panel cutouts are as
shown below.
(according to DIN43700).
Note: 1. The mounting panel thickness
should be 1 to 5 mm.
2. To allow easier operability, it is
recommended that Adapters are
mounted so that the gap between
sides with hooks is at least 15 mm
(i.e., so that the panel cutout interval
is at least 60 mm).
3. It is possible to mount counters
side by side, but only in the
direction without the hooks.
If they are mounted side-by-side,
water-resistant specifications
cannot be ensured.
0
With Y92A-48F1 attached.
A = {48n2.5 + (n1) x 4}+1
0
With Y92A-48 attached.
A = (51n5.5)+1
48×48
44.8×44.8
72.5 14.4
6
HLD
TAC HOMETER
HLD
HLD
TAC HOMETER
HLD
(51)
Panel
Y92S-29 (order separately)
Waterproof Packing Y92F-30 (order separately)
Flush Mounting Adapter
P3GA-11
(order separately)
Back Connecting
Socket
58
48 7.5 98.7
109.7
112
P2CF-11(-E) (order separately)
Front Connecting Socket
H7CX-R11/-R11D1
H7CX-R
50
Accessories (Order Separately)
Note: All units are in millimeters unless otherwise indicated.
40±0.2
7.8 34.5
35.4
4
7.8
4
40±0.2
35.4
30
54.5
3
1.2
Track Mounting/Front Connecting Socket
P2CF-11
Surface Mounting Holes
Two, 4.5 dia. or two, M4
70 max.
50 max. 31.2 max.
70 max.
50 max. 31.2 max.
Note: Track mounting is also possible.
P2CF-11-E (Finger-safe Terminal Type)
Conforming to VDE0106/P100
Eleven,
M3.5 x 7.5 sems
Two, 4.5-dia.
holes
Terminal Arrangement/
Internal Connections
(Top View)
Eleven,
M3.5 x 7.5 sems
Two, 4.5-dia.
holes
45
45
25.6
4.5 16.3 6.2
34
47.7 x 47.7 48 x 48
47.4
16.5 24.6 27.6
Back Connecting Socket
P3GA-11
27 dia.
Twelve, 6.4-dia. holes
Note: Finger protection can be ensured by using in combination with the Y92A-48G Terminal Cover.
Finger-safe Terminal Cover
Conforming to VDE0106/P100
Y92A-48G
(Attachment for P3GA-11
Socket)
Terminal Arrangement/
Internal Connections
(Bottom View)
H7CX-R
51
Operating Procedures
Settings for Basic Operations
Note: 1. The characters displayed in reverse video are the default
settings.
2. Changes in DIP switch settings are enabled when the power
is turned ON.
Settings for basic functions are performed with the DIP switch.
1
OFF
ON
2345678
(Factory setting)
Item OFF ON
1 Not used
2 Counting speed 30 Hz 10 kHz
3 Output mode Refer to the table on the right.
4
5 Average processing Refer to the table on the right.
6
7 Not used
8 NPN/PNP input mode NPN PNP
Easy Confirmation of Switch Settings Using Indicators
The ON/OFF status of the DIP switch pins can be
confirmed using the front display. For details, refer to page 57.
Pin 3 Pin 4 Output mode
OFF OFF Upper and lower limit
ON OFF Area
OFF ON Upper limit
ON ON Lower limit
Pin 5 Pin 6 Average processing
OFF OFF OFF (no average processing)
ON OFF 2 times
OFF ON 4 times
ON ON 8 times
H7CX-R
52
Settings for Advanced Functions
(99.9s)(0.0s)
(999.9s)(0.1s)
(99.999)(1.000)(0.001)
(KP-1) (KP-2) (KP-3) (KP-4) (KP-5)
(See note 2.)(See note 1.)
3s min. 3s min.
Power ON
The characters displayed in reverse video are the initial values.
For details on operations in run mode, refer to page 54.
Settings that cannot be performed with the DIP switch are performed with the operation keys.
Run mode
Function setting mode
Note: 1. If the mode is switched to the function setting mode during operation, operation will
continue.
2. Changes made to settings in function setting mode are enabled for the first time when
the mode is changed to run mode. Also, when settings are changed, the counter is
reset (measured values initialized and output turned OFF) on returning to run mode.
Key protect
level
(KYPT)
Startup
time
(STMR)
Auto-zero
time
(AUTZ)
Prescale
value
(PSCL)
Decimal
point
position
(DP)
(No decimal
point)
(One digit
after decimal
point)
(Two digits
after decimal
point)
(Three digits
after decimal
point)
Set the decimal point position using the key.
Set the value of each corresponding digit with the key.
Set the value of each corresponding digit with the key.
Set the value of each corresponding digit with the key.
Set the key protect level with the key.
H7CX-R
53
Explanation of Functions
Basic Functions
(setting is performed with DIP switch)
Counting Speed
Set the maximum counting speed (30 Hz/10 kHz) for input. If con-
tacts are used for input signals, set the counting speed to 30 Hz. Pro-
cessing to eliminate chattering is performed for this setting.
Output Mode
Set the output method for control output based on the comparison
value. Upper and lower limit (HI-LO), area (AREA), upper limit (HI),
and lower limit (LO) can be set. (For details on the operation of the
output modes, refer to Output Mode Settings on page 56.)
Average Processing
Flickering display and output chattering can be prevented using aver-
age processing (simple averaging). Average processing can be set to
one of four levels: no average processing, 2 times (i.e., the average
of 2 measurement values), 4 times, or 8 times. For 5 Hz or higher,
the measurement cycle will be equal to the sampling cycle (200 ms)
multiplied by the averaging setting (i.e., the number of times). For
less than 5 Hz, the frequency will be measured when the input pulse
comes. Average processing enables fluctuating input signals to be
displayed stably. Set the optimum number of times for the applica-
tion.
NPN/PNP Input Mode
Select either NPN input (no-voltage input) or PNP input (voltage
input) as the input format. When using a two-wire sensor, select NPN
input. The same setting is used for all external inputs. For details on
input connections, refer to Input Connections on page 47.
Advanced Functions
(setting is performed with operation keys)
Decimal Point Position (dp)
Decide the decimal point position for the measurement value and
comparison value.
Prescale Value (pscl)
It is possible to display the rate of rotation or the speed of a device or
machine to which the H7CX-R is mounted by converting input pulses
to a desired unit. If this prescaling function is not used, the input fre-
quency (Hz) will be displayed.
The relationship between display and input is determined by the fol-
lowing equation. Set the prescale value according to the unit to be
displayed.
Displayed value = f × a
f: Input pulse frequency (number of pulses in 1 second)
a: Prescale value
1. Displaying Rotation Rate
N: Number of pulses per revolution
Example:In order to display the rate of rotation for a machine that
outputs 5 pulses per revolution in the form @@.@rpm:
1. Set the decimal point position to 1 decimal place.
2. Using the formula, set the prescale value to 1/N × 60 =
60/5 = 12.
2. Displaying Speed
N: Number of pulses per revolution
d: Diameter of rotating body (m)
πd: Circumference (m)
Note: If the prescale value setting is incorrect, a counting error will oc-
cur. Check that the settings are correct before using this func-
tion.
Auto-zero Time (aut=)
It is possible to set the H7CX-R so that if there is no pulse for a cer-
tain time the display is force-set to 0. This time is called the auto-zero
time.
Note: Set the auto-zero time to a time slightly longer than the estimat-
ed interval between input pulses and within the setting range
(0.1 to 999.9 s). It will not be possible to make accurate mea-
surements if the auto-zero time is set to a time shorter than the
input pulse cycle. Setting a time that is too long may also result
in problems, such as a time-lag between rotation stopping and
the alarm turning ON.
Startup Time (stmr)
In order to prevent undesired output resulting from unstable input
immediately after the power supply is turned ON, it is possible to pro-
hibit measurement for a set time (0.0 to 99.9 s), the startup time. It
can also be used to stop measurement and disable output until the
rotating body reaches the normal rate of rotation, after the power
supply to the H7CX-R and rotating body are turned ON at the same
time.
Display unit Prescale value (a)
rpm 1/N × 60
rps 1/N
Display unit Prescale value (a)
m/min πd × 1/N × 60
m/s πd × 1/N
d: Diameter of
rotating body
Startup time
Display
Power supply
Time
Output
(lower limit)
Comparison
value
(lower limit)
H7CX-R
54
Key Protect Level (kypt)
Set the key protect level.
When the key-protect switch is set to ON, it is possible to prevent setting errors by prohibiting the use of certain operation keys by specifying the
key protect level (KP-1 to KP-5). The key protect level is set in the function setting mode. The key protect indicator is lit while the key-protect
switch is set to ON. Confirm the ON/OFF status of the key-protect switch after the H7CX is mounted to the panel.
Note: Changing mode to DIP switch monitor mode or function setting mode.
Note: Factory-set to OFF
Key protect indicator
ON
OFF
(See note)
Level Meaning Details
Changing mode
(See note.)
Switching display
during operation
Hold key Up key
KP-1 (default setting) No Yes Yes Yes
KP-2 No Yes No Yes
KP-3 No Yes Yes No
KP-4 No Yes No No
KP-5 NoNoNoNo
H7CX-R
55
Operation in Run Mode
Set the values for each digit as required using the key.
Measurement value
Measurement value
Comparison value
Measurement Value
Displays the currently measured value.
Comparison Value
Set comparison value. The measurement value is
compared to comparison value and output is made
according to the selected output mode.
Measurement value
Measurement value
Comparison value 1
Measurement value
Comparison value 2
Measurement Value
Displays the currently measured value.
Comparison Value 1/Comparison Value 2
Set comparison value 1 and comparison value 2. The
measurement value is compared to comparison value 1
and comparison value 2 and output is made according
to the selected output mode.
Output Mode: HI-LO or AREA
Output Mode: HI or LO
H7CX-R
56
Output Mode Settings
Hold Function
The measurement value (display value) and output are sustained while the hold input is ON.
Note: The output will maintain the current status when the hold key is pressed.
Example
Output
mode
setting
Upper
and
lower
limit
(HI-LO)
Area
(AREA)
Condition Comparison value 1 Comparison value 2 Comparison value 1 > Comparison value 2
ON
condition
Comparison value 1 measurement value
Comparison value 2
Comparison value 2 measurement value
Comparison value 1
Upper
limit
(HI)
Lower
limit
(LO)
OUT
Measurement value
ON condition: measurement value comparison value 1 or measurement value comparison value 2
Note: When comparison value 1 comparison value 2, the output is always ON regardless of the
comparison value.
Comparison value 2
(Upper-limit)
Comparison value 1
(Lower-limit)
OUT
Comparison value 1
Comparison value 2
Measurement value
OUT
Measurement value
ON condition: Measurement value Comparison value
Comparison value
(Upper-limit)
OUT
Measurement value
ON condition: Measurement value Comparison value
Comparison value
(Lower-limit)
Output mode
setting
Operation
Lower limit
(LO)
OUT
Display value
Actual input
Sustained display value
Sustained output
Hold input
(Hold Key)
Comparison value
(Lower-limit)
H7CX-R
57
Self-diagnostic Function
The following displays will appear if an error occurs.
Note: 1. Includes the case where the EEPROM has reached its overwrite lifetime.
2. Occurs when the measurement value reaches 999,999.
3. Display flashes (1-second cycles).
Operation in DIP Switch Monitor Mode
The H7CX-R is also equipped with a DIP switch monitor function, a convenient function that enables the settings of the DIP switch pins to be con-
firmed using the front display.
Note: When the mode is changed to DIP switch monitor, the measurement value is reset, outputs turns OFF, and measuring stops.
Main display Sub-display Error Output status Correction method Set value after
reset
ffffff
(See note 3.)
No change Measurement value overflow
(See note 2.)
No change Measurement value 999999 No change
e1 Not lit CPU OFF Either press the hold key or reset the
power supply.
No change
e2 Not lit Memory error (RAM) OFF Reset the power supply. No change
e2 sum Memory error (EEP)
(See note 1.)
OFF Reset to the factory settings using the
hold key.
0
1
+
12345678
Indicates that DIP switch pin 8 is ON.
Indicates that DIP switch pin 7 is OFF.
Indicates that DIP switch pin 6 is ON.
Indicates that DIP switch pin 5 is OFF.
Indicates that DIP switch pin 4 is ON.
Indicates that DIP switch pin 3 is OFF.
Indicates that DIP switch pin 2 is ON.
Indicates that DIP switch pin 1 is OFF.
Example
Run Mode
DIP Switch Monitor Mode
Measurement stopped
Measurement possible
Power ON
1 s min.
(See note.)
1
1
To change the mode to DIP switch monitor mode, press the
Key for 1 s min. with the key held down. The mode will not
change if the key is pressed first.
DIP switch
monitor
The status of the DIP switch pins (1 to 8) can be confirmed using the
keys.
ON
OFF
1
HLD
HLD
TACHOMETER
H7CX-R
58
Additional Information
Key Operation Flowchart
Note: All setting changes are performed using the key.
Lists of Settings
Run Mode
Function Setting Mode
Parameter name Parameter Setting range Default value Unit Set value
Measurement value --- 0 to 999999 0 --- ---
Measurement value,
Comparison value
Measurement value --- 0 to 999999 0 --- ---
Comparison value --- 0 to 999999 0 ---
Measurement value,
Comparison value 1
Measurement value --- 0 to 999999 0 --- ---
Comparison value 1 --- 0 to 999999 0 ---
Measurement value,
Comparison value 2
Measurement value --- 0 to 999999 0 --- ---
Comparison value 2 --- 0 to 999999 0 ---
1
+
1
+
Power ON
Run mode
1 s min.
1 s min.
3 s min.
3 s min.
Measurement value
Decimal point position
Prescale value
Auto-zero time
Startup time
Key protect level
DIP switch monitor mode
DIP switch monitor
Measurement stopped
Measurement possible
Function setting mode
Measurement value,
Comparison value
Measurement value
Measurement value,
Comparison value 1
Measurement value,
Comparison value 2
Output Mode: HI or LO
Output Mode: HI-LO or AREA
Parameter name Parameter Setting range Default value Unit Set value
Decimal point position dp ------/-----.-/----.--/---.--- ------ ---
Prescale value pscl 0.001 to 99.999 1.000 ---
Auto-zero time aut= 0.1 to 999.9 999.9 s
Startup time stmr 0.0 to 99.9 0.0 s
Key protect level kypt kp-1/kp-2/kp-3/kp-4/kp-5 kp-1 ---
H7CX
59
Safety Precautions (Common)
Refer to Safety Precautions for All Counters.
Note: The following precautions are common for all H7CX models.
Loose screws may occasionally result in fire or malfunction.
Tighten the terminal screws securely. The recommended
tightening torque is 0.5 N·m.
There may occasionally be a risk of explosion. Do not use the
product where flammable or combustion gases are present.
If the output relay is used beyond its life expectancy, its contacts
may occasionally become fused or there may occasionally be a risk
of fire. The life expectancy of the output relay varies considerably
according to its usage.
Use the output relay within its rated load and electrical life
expectancy.
This may occasionally cause electric shock, fire or malfunction.
Never disassemble, repair or modify the product.
This may occasionally cause electric shock, fire or malfunction.
Do not allow metal fragments or lead wire scraps to fall inside this
product.
Precautions for Safe Use
Operating and Storage Conditions
Do not use in locations affected by excessive vibration or shock, or
in locations subject to exposure to water or oil.
Do not use the product in locations subject to dust, corrosive
gases, or direct sunlight.
Separate the input signal devices, input signal cables, and the
product from the source of noise or high-tension cables producing
noise.
Separate the product from the source of static electricity when
using the product in an environment where a large amount of static
electricity is produced (e.g., forming compounds, powders, or fluid
materials being transported by pipe).
Organic solvents (such as paint thinner), as well as very acidic or
basic solutions might damage the outer casing of the H7CX.
Use the product within the ratings specified for temperature and
humidity.
Do not use the product in locations where condensation may occur
due to high humidity or where temperature changes are severe.
Store at the specified temperature. If the H7CX has been stored at
a temperature of less than –10°C, allow the H7CX to stand at room
temperature for at least 3 hours before use.
Usage Precautions
Make sure that the voltage applied is within the specified range,
otherwise the internal elements of the counter may be damaged.
The load current must be within the rated current.
Ensure that the power is turned OFF before changing DIP switch
settings. Changing DIP switch settings with the power turned ON
may result in electric shock due to contact with terminals subject to
high voltages.
Pay attention to terminal polarity to ensure correct wiring.
Make sure that the fluctuation of the supply voltage is within the
permissible range.
Apply the power supply voltage through a relay or switch in such a
way that the voltage reaches the rated value within 2 s. If the
voltage is applied gradually, the power may not be reset or unstable
output operations may result.
Set each set value to match the item being counted (or measured).
Not matching the content of the set values with the counted (or
measured) items may cause unexpected operations resulting in
injury or damage to the equipment.
Leaving the H7CX with outputs ON at a high temperature for a long
time may hasten the degradation of internal parts (such as
electrolytic capacitors). Therefore, use the product in combination
with relays and avoid leaving the product as long as more than 1
month with the output turned ON.
When the product is operated with no-voltage input (NPN input),
approximately 14 V is output from the input terminals, so connect a
diode if the external power supply is less than 14 V.
Install a switch or circuit-breaker that allows the operator to
immediately turn OFF the power, and make sure it is labeled
clearly.
The H7CX’s panel surface is water-resistive (conforming to NEMA
4, UL Type 4X, and IP66). In order to prevent the internal circuit
from water penetration through the space between the H7CX and
operating panel, attach a waterproof packing between the H7CX
and installation panel and secure the waterproof packing with the
Y92F-30 Flush-mounting Adapter.
Tighten the two mounting screws on the Adapter. Tighten them
alternately, a little at a time, so as to keep them at an equal
tightness. If the panel screws are tightened unequally, water may
ingress inside the panel.
CAUTION
X
X1T X2
X1/aX2/b T/a X1/a
Auxiliary relay
(e.g., MY Relay)
Input0 V
Sensor
0.5 to 1 mm
It is recommended that the space between
the screw head and the adapter should be
0.5 to 1 mm.
H7CX
60
Precautions for Correct Use
External Power Supply
The capacity of the external power supply is 100 mA at 12 V. When
using a 24 VAC/12 to 24 VDC power supply, reduce the load with the
power supply voltage, as shown in the following diagram (DC power
supplies only).
Power Supplies
Turn the power ON and OFF using a relay with a rated capacity of
10 A minimum to prevent contact deterioration due to inrush current
caused by turning the power ON and OFF.
Be sure that the capacity of the power supply is large enough,
otherwise the H7CX may not start due to inrush current (reference
value: approx. 10 A, 1.5 ms at 26.4 VAC) that may flow for an
instant when the H7CX is turned ON.
Power Failure Backup
All data is stored in the EEPROM when there is a power failure. The
EEPROM can be overwritten more than 100,000 times. EEPROM is
overwritten when the power is turned OFF or when settings are
changed.
Conformance to EN/IEC
Standards
Specifications call for basic insulation between the power supply
and input terminals, between the power supply and output
terminals, and between the input and output terminals. (The H7CX-
A@D is not insulated between the power supply and input
terminals.)
Input and output terminals are connected to devices without
exposed charged parts.
Input and output terminals are connected to devices with basic
insulation that is suitable for the maximum operating voltage.
10.8 15
100
20
Power supply voltage (VDC)
(DC voltage supply only)
Load current (mA)
H7CX
61
Safety Precautions (H7CX-A)
Precautions for Safe Use
Changing the Set Values
When changing the set value during operation, because the H7CX
uses a constant read-in system, output will turn ON if the set value is
equal to the present value.
Precautions for Correct Use
Power Supplies
When turning the power ON and OFF, input signal reception is
possible, unstable, or impossible as shown in the diagram below.
Transistor Output
The transistor output of the H7CX is isolated from the internal
circuitry by a photocoupler, so the transistor output can be used as
both NPN and PNP output.
The diode connected to the collector of the output transistor is used
to absorb inverted voltage that is generated when an inductive load
is connected to the H7CX.
Operation with a Set Value and Present
Value of 0
If the set value and present value are both 0, output will turn ON.
Output will turn OFF during reset.
Using the Prescaling Function
Observe the following points when setting a prescale value.
Set the set value to a value less than {Maximum countable value
Prescale value}.
Example: If the prescale value is 1.25 and the counting range is
0.000 to 999.999, set the set value to a value less than
998.749 (= 999.999 1.25).
If the set value is set to a value greater than this, output will not turn
ON.
Note: Output will turn ON, however, if a present value overflow occurs
(FFFFFF or FFFF).
Setting the prescale value incorrectly may result in incorrect
counting operation. Be sure to set the prescale value correctly.
Response Delay Time When Resetting
(Transistor Output)
The following table shows the delay from when the reset signal is
input until the output is turned OFF.
(Reference values)
Output Delay Time
The following table shows the delay from when the present value
passes the set value until the output is produced.
Actual measurements in N and K-2 modes. (Reference values)
Note: The above times may vary slightly depending on the mode or
operating conditions.
Maximum Counting Speed for Batch
Counter
The maximum counting speed for batch counter operation is 5 kHz.
The batch counter counts the number of times the count reaches the
set value.
200 ms 5 ms
ON
OFF
Input Impossible
Unstable
Possible
Unstable
Impossible
0 to 1 s0 to 90 ms
Power
supply
++
Power for load Power for load
Load Load
NPN output PNP output
+
Counter
Power for load
Inductive load
Minimum reset signal width Output delay time
1 ms 0.8 to 1.2 ms
20 ms 15 to 25 ms
Control output type Maximum counting
speed
Output delay time
Contact output 30 Hz 16.5 to 24.0 ms
5 kHz 3.7 to 5.6 ms
Transistor output 30 Hz 12.0 to 20.0 ms
5 kHz 0.2 to 0.55 ms
H7CX
62
Safety Precautions (H7CX-R)
Precautions for Safe Use
Changing the Measurement Value
The H7CX-R uses a constant read-in system, so the output status is
affected when the comparison values are changed during operation
such that the present measurement value falls within the range of the
upper- and lower-limit comparison values.
Turning ON the Power using the
Factory Settings
When the power is turned ON using the factory settings, the output
will turn ON after 999.9 s if no pulses are received as count input.
Precautions for Correct Use
Comparison Value Settings
In upper and lower limit output mode, if the comparison value setting
is such that comparison value 1 comparison value 2, the output will
always be ON.
Using the Prescaling Function
Setting the prescale value incorrectly may result in incorrect counting
operation. Be sure to set the prescale value correctly.
In the interest of product improvement, specifications are subject to change without notice.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2008.12
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2008 All Right Reserved.