PCB Relay G2RL 223
■Approved Standards
UL Recognized (File No. E41643) / CSA Certified (File No. LR31928) - - Ambient Temp. = 40°C
Note: Consult Omron for additional UL / CSA ratings
VDE (EN61810-1) (License No. 119650)
Note: To achieve approved life cycles on sealed models, the relay should be vented by removing the “knock off vent nib” on top of relay case after
the soldering/washing process.
Electrical Life Data
Note: 1. The results shown reflect values measured using very severe test conditions i.e., Duty: 1 s ON/1 s OFF.
2. In order to obtain the full rated life cycles on the fully sealed models, the relay should be properly vented by removing the “knock off vent
nib” on top of the relay case after the soldering/washing process.
3. Electrical endurance will vary depending on the test conditions. Contact your OMRON representative if you require more detailed
information for the electrical endurance under your test conditions.
Model Contact form Coil ratings Contact ratings
G2RL-1A SPST-NO 3 to 48 VDC 12 A at 250 VAC (General use)
G2RL-1 SPDT 12 A at 24 VDC (Resistive)
G2RL-1A-E SPST-NO 3 to 48 VDC 16 A at 250 VAC (General use)
G2RL-1-E SPDT 16 A at 24 VDC (Resistive)
G2RL-1A-H SPST-NO 5 to 24 VDC 10 A at 250 VAC (General use)
10 A at 24 VDC (Resistive)
G2RL-1-H SPDT
G2RL-2A DPST-NO 3 to 48 VDC 8 A at 277 VAC (General use)
8 A at 30 VDC (Resistive)
G2RL-2 DPDT
Model Contact form Coil ratings Contact ratings
G2RL-1(A) 1 pole 5, 12, 18, 22, 24, 48 VDC 12 A at 250 VAC (cosφ=1)
12 A at 24 VDC (L/R=0 ms)
AC15: 3 A at 240 VAC
DC13: 2.5 A at 24 VDC, 50 ms
G2RL-1(A)-E 1 pole 5, 12, 18, 22, 24, 48 VDC 16 A at 250 VAC (cosφ=1)
16 A at 24 VDC (L/R=0 ms)
AC15: 3 A at 240 VAC (NO)
1.5 A at 240 VAC (NC)
DC13: 2.5 A at 24 VDC (NO), 50 ms
G2RL-1(A)-H 1 pole 5, 9, 12, 24 VDC 10 A at 250 VAC (cosφ=1)
10 A at 24 VDC (L/R=0 ms)
G2RL-2(A) 2 poles 5, 12, 18, 22, 24, 48 VDC 8 A at 250 VAC (cosφ=1)
8 A at 24 VDC (L/R=0 ms)
AC15: 1.5 A at 240 VAC
DC13: 2 A at 30 VDC, 50 ms
G2RL-1-E 16 A at 250 VAC (cosφ=1) 30,000 operations min.
16 A at 24 VDC 30,000 operations min.
8 A at 250 VAC (cosφ=0.4) 200,000 operation min. (normally open side operation)
8 A at 30 VDC (L/R=7 ms) 10,000 operation min. (normally open side operation)
G2RL-1 12 A at 250 VAC (cosφ=1) 50,000 operations min.
12 A at 24 VDC 30,000 operations min.
5 A at 250 VAC (cosφ=0.4) 150,000 operation min. (normally open side operation)
5 A at 30 VDC (L/R=7 ms) 20,000 operation min. (normally open side operation)
G2RL-1-H 10 A at 250 VAC (cosφ=1) 100,000 operations min.
10 A at 24 VDC 50,000 operations min.
G2RL-2 8 A at 250 VAC (cosφ=1) 30,000 operations min.
8 A at 30 VDC 30,000 operations min.