Type 12 Modular Enclosures Type 12 Free-Standing Modular Enclosure Disconnects Modular Encl. Detail Sheet see universal opening detail 4.00 3.37 (102) (86) 1.12 B (28) A .28 D (7) (TYP) panel this area represents disconnect switch or circuit breaker C 9.93 9.31 (252) (236) panel 2.75 (70) 3.00 D (76) 1.62 (41) Flange Mounting Universal Opening Detail The dimensional information provided in this drawing is derived from information supplied by the manufacturer of the equipment to be installed. Fit and function of all equipment should be checked before and after installation to assure proper and safe operation and compliance with the applicable regulations, codes and standards. Universal opening must be filled with an operator adapter kit for the specific brand and type of disconnect being used, (see page 381). Important Note When ordering modular enclosure systems, be sure to include all the necessary components. 1. Disconnect master or slave enclosure 2. Gasket kits and/or end plates (see page 259) 3. Operator adapter plates MUST be ordered for the specific brand and type of disconnect being used, (see page 381) Disconnect switch (or circuit breaker), operating handle and operating mechanism are not furnished with enclosure, see disconnect ordering information, pages 260 - 270. Notes: Refer to detail sheet for drawing information and associated dimensions. Dimensions are in inches. Millimeters shown are for reference only. Data subject to change without notice. 260 Type 12 Modular Enclosures Type 12 Free-Standing Modular Enclosure Disconnects Allen-Bradley(R) 1949V Disconnect Mechanism Amp DS30 Fuse Clip Rating Fuse Enclosure Height 72 Class Amp Volt 30A (non) (non) DS30 30A (non) DS30 30A 30A DS30 30A DS30 84 A B A B D(1) C in. mm in. mm in. mm in. mm in. mm in. mm -- 7.87 200 6.00 152 13.73 349 11.50 292 4.00 102 6.75 171 (non) - 11.87 301 10.00 254 17.37 441 15.50 394 4.00 102 6.75 171 250V H,K,R 11.87 301 10.00 254 17.37 441 15.50 394 5.25 133 6.75 171 30A 600V H,K,R 11.87 301 10.00 254 17.37 441 15.50 394 8.00 203 6.75 171 30A 30A 600V J 11.87 301 10.00 254 17.37 441 15.50 394 5.25 133 6.75 171 DS30 30A 60A 250V H,K 11.87 301 10.00 254 17.37 441 15.50 394 6.00 152 6.75 171 DS30 30A 60A 600V H,K 11.87 301 10.00 254 17.37 441 15.50 394 8.50 216 6.75 171 DS30 30A 60A 600V J 11.87 301 10.00 254 17.37 441 15.50 394 5.50 140 6.75 171 DS60 60A (non) (non) - 11.87 301 9.87 251 17.37 441 15.37 394 4.00 102 6.75 171 DS60 60A 30A 600V H,K,R 11.87 301 9.87 251 17.37 441 15.37 394 8.00 203 6.75 171 DS60 60A 60A 250V H,K,R 11.87 301 9.87 251 17.37 441 15.37 394 6.00 152 6.75 171 DS60 60A 60A 600V H,K,R 11.87 301 9.87 251 17.37 441 15.37 394 8.50 216 6.75 171 DS60 60A 60A 600V J 11.87 301 9.87 251 17.37 441 15.37 394 5.50 140 6.75 171 DS60 60A 100A 250V H,K 11.87 301 9.87 251 17.37 441 15.37 394 8.50 216 6.75 171 DS60 60A 100A 600V H,K 11.87 301 9.87 251 17.37 441 15.37 394 10.50 267 6.75 171 DS60 60A 100A 600V J 11.87 301 9.87 251 17.37 441 15.37 394 7.25 184 6.75 171 DS100 100A (non) (non) - 11.87 301 8.37 251 17.37 441 13.87 352 4.75 121 8.00 203 DS100 100A 100A 250V H,K,R 11.87 301 8.37 251 17.37 441 13.87 352 10.50 267 8.00 203 DS100 100A 100A 600V H,K,R 11.87 301 8.37 251 17.37 441 13.87 352 12.50 318 8.00 203 DS100 100A 100A 600V J 11.87 301 8.37 251 17.37 441 13.87 352 9.25 235 8.00 203 DS100 100A 200A 250V H,K 11.87 301 8.37 251 17.37 441 13.87 352 11.25 286 8.00 203 DS100 100A 200A 600V H,K 11.87 301 8.37 251 17.37 441 13.87 352 13.75 349 8.00 203 DS100 100A 200A 600V J 11.87 301 8.37 251 17.37 441 13.87 352 10.00 254 8.00 203 DS200 200A (non) (non) - 10.43 265 6.00 102 15.93 405 11.50 292 10.00 254 11.00 279 DS200 200A 200A 250V H,K,R 10.43 265 6.00 102 15.93 405 11.50 292 15.00 381 11.00 279 DS200 200A 200A 600V H,K,R 10.43 265 6.00 102 15.93 405 11.50 292 17.25 438 11.00 279 DS200 200A 200A 600V J 10.43 265 6.00 102 15.93 405 11.50 292 13.50 343 11.00 279 DS200 200A 400A 250V H,K 10.43 265 6.00 102 15.93 405 11.50 292 15.75 400 11.00 279 DS200 200A 400A 600V H,K 10.43 265 6.00 102 15.93 405 11.50 292 18.75 476 11.00 279 DS200 200A 400A 600V J 10.43 265 6.00 102 15.93 405 11.50 292 14.25 362 11.00 279 DS400 400A (non) (non) - * * * * 15.93 405 9.62 244 10.75 273 11.00 279 DS400 400A 400A 250V H,K,R * * * * 15.93 405 9.62 244 16.25 413 11.00 279 DS400 400A 400A 600V H,K,R * * * * 15.93 405 9.62 244 19.25 489 11.00 279 DS400 400A 400A 600V J * * * * 15.93 405 9.62 244 14.75 375 11.00 279 Allen-Bradley Mechanism for Circuit Breakers Amp Circuit Breaker Type Enclosure Height 72 Manufacturer Frame(s) in. M40 150A General Electric M40 150A Westinghouse F (series C) M50 250A Westinghouse J (series C) M60 400A Westinghouse K (series C) 84 A B A B D(1) C mm in. mm in. mm in. mm in. mm in. mm 301 11.25 286 17.37 441 16.75 425 5.75 146 4.75 121 11.87 301 11.25 286 17.37 441 16.75 425 5.00 127 4.75 121 11.87 301 10.87 276 17.37 441 16.37 416 9.75 248 5.00 127 11.87 301 10.62 270 17.37 441 16.12 409 9.75 248 6.25 159 TED, THED, TEC 11.87 * Do not install disconnects in this height enclosure. (1) Dimension "D" does not include space for auxiliary switches. The dimensional information provided in this table is derived from information supplied by the manufacturer of the equipment to be installed. Fit and function of all equipment should be checked before and after installation to assure proper and safe operation and compliance with the applicable regulations, codes and standards. Notes: Refer to detail sheet for drawing information and associated dimensions. Dimensions are in inches. Millimeters shown are for reference only. Data subject to change without notice. 261 Modular Encl. Allen-Bradley Mechanism for Switches Type 12 Modular Enclosures Type 12 Free-Standing Modular Enclosure Disconnects Allen-Bradley (R) Modular Encl. 1494V Disconnect Mechanism Allen-Bradley Mechanism for Switches Amp N30 Fuse Clip Rating Fuse Enclosure Height 72 Class 84 A B A B D(1) Amp Volt C in. mm in. mm in. mm in. mm in. mm in. mm 30A (NON) (NON) - 9.87 251 9.37 238 15.37 390 14.87 378 4.75 121 6.50 165 NF30 30A 30A 250V H,K,R 9.87 251 9.37 238 15.37 390 14.87 378 6.50 165 6.50 165 NF30 30A 30A 600V H,K,R 9.87 251 9.37 238 15.37 390 14.87 378 9.25 235 6.50 165 NF30 30A 30A 600V J 9.87 251 9.37 238 15.37 390 14.87 378 6.50 165 6.50 165 NF30 30A 60A 250V H,K,R 9.87 251 9.37 238 15.37 390 14.87 378 7.25 184 6.50 165 NF30 30A 60A 600V H,K,R 9.87 251 9.37 238 15.37 390 14.87 378 9.75 248 6.50 165 NF30 30A 60A 600V J 9.87 251 9.37 238 15.37 390 14.87 378 6.75 171 6.50 165 N60 60A (NON) (NON) - 9.87 251 8.62 238 15.37 390 14.12 378 4.75 121 6.50 165 NF60 60A 30A 600V H,K,R 9.87 251 8.62 238 15.37 390 14.12 378 10.50 267 6.50 165 NF60 60A 60A 250V H,K,R 9.87 251 8.62 238 15.37 390 14.12 378 8.50 216 6.50 165 NF60 60A 60A 600V H,K,R 9.87 251 8.62 219 15.37 390 14.12 378 11.00 279 6.50 165 NF60 60A 60A 600V J 9.87 251 8.62 219 15.37 390 14.12 378 7.75 197 6.50 165 NF60 60A 100A 250V H,K,R 9.87 251 8.62 219 15.37 390 14.12 378 11.00 279 6.50 165 NF60 60A 100A 600V H,K,R 9.87 251 8.62 219 15.37 390 14.12 378 13.00 330 6.50 165 NF60 60A 100A 600V J 9.87 251 8.62 219 15.37 390 14.12 378 9.75 248 6.50 165 N100 100A (NON) (NON) - 9.87 251 6.75 171 15.37 390 12.25 311 4.75 121 7.25 184 NF100 100A 100A 250V H,K,R 9.87 251 6.75 171 15.37 390 12.25 311 11.50 292 7.50 191 NF100 100A 100A 600V H,K,R 9.87 251 6.75 171 15.37 390 12.25 311 13.50 343 7.50 191 NF100 100A 100A 600V J 9.87 251 6.75 171 15.37 390 12.25 311 10.25 260 7.50 191 NF100 100A 200A 250V H,K,R 9.87 251 6.75 171 15.37 390 12.25 311 12.25 311 7.75 197 NF100 100A 200A 600V H,K,R 9.87 251 6.75 171 15.37 390 12.25 311 14.75 375 7.75 197 NF100 100A 200A 600V J 9.87 251 6.75 171 15.37 390 12.25 311 11.00 279 7.75 197 N200 200A (NON) (NON) - 8.56 217 5.12 130 14.06 357 10.62 270 7.25 184 10.50 267 NF200 200A 200A 250V H,K,R 8.56 217 5.12 130 14.06 357 10.62 270 15.00 381 10.50 267 NF200 200A 200A 600V H,K,R 8.56 217 5.12 130 14.06 357 10.62 270 17.50 445 10.50 267 NF200 200A 200A 600V J 8.56 217 5.12 130 14.06 357 10.62 270 13.75 349 10.50 267 NF200 200A 400A 250V H,K,R 8.56 217 5.12 130 14.06 357 10.62 270 16.50 419 11.00 279 NF200 200A 400A 600V H,K,R 8.56 217 5.12 130 14.06 357 10.62 270 19.50 495 11.00 279 NF200 200A 400A 600V J 8.56 217 5.12 130 14.06 357 10.62 270 15.00 381 11.00 279 1494D Disconnect Mechanism Allen-Bradley Mechanism for Circuit Breakers (1) Circuit Breaker Type Enclosure Height Amp 72 Manufacturer Frame(s) 84 A B in. mm in. A B (1) C D mm in. mm in. mm in. mm in. mm 117 N4/N40 150A General Electric TED, THED, TEC 9.87 251 9.25 235 15.37 390 14.75 375 5.87 149 4.62 N5/N55 225A General Electric TFK, THFK, TFC 9.87 251 8.50 216 15.37 390 14.00 356 8.87 225 4.75 121 N4/N40 150A Westinghouse F (series C) 9.87 251 9.25 235 15.37 390 14.75 375 5.87 149 4.62 117 N5/N50 250A Westinghouse J (series C) 9.87 251 8.50 216 15.37 390 14.00 356 8.87 225 4.75 121 Dimension "D" does not include space for auxiliary switches. The dimensional information provided in this table is derived from information supplied by the manufacturer of the equipment to be installed. Fit and function of all equipment should be checked before and after installation to assure proper and safe operation and compliance with the applicable regulations, codes and standards. Notes: Refer to detail sheet for drawing information and associated dimensions. Dimensions are in inches. Millimeters shown are for reference only. Data subject to change without notice. 262 Type 12 Modular Enclosures Type 12 Free-Standing Modular Enclosure Disconnects Culter-Hammer(R) C361 Disconnect Mechanism Fuse Clip Rating Amp Fuse Enclosure Height 72 Class Amp Volt 84 A B A B C D in. mm in. mm in. mm in. mm in. mm in. mm NC 30A (non) (non) - 11.87 301 10.50 267 17.37 441 16.00 406 4.75 121 6.25 159 SC21 30A 30A 250V H,K,R 11.87 301 10.50 267 17.37 441 16.00 406 7.75 197 6.25 159 SC61 30A 30A 600V H,K,R 11.87 301 10.50 267 17.37 441 16.00 406 7.75 197 6.25 159 SC61 30A 60A 250V H,K,R 11.87 301 10.50 267 17.37 441 16.00 406 8.25 210 6.25 159 ND 60A (non) (non) - 11.87 301 10.50 267 17.37 441 16.00 406 4.75 121 6.25 159 SD22 60A 30A 600V J 11.87 301 10.50 267 17.37 441 16.00 406 7.75 197 6.25 159 SD22 60A 60A 250V H,K,R 11.87 301 10.50 267 17.37 441 16.00 406 8.25 210 6.25 159 SD62 60A 60A 600V H,K,R 11.87 301 10.50 267 17.37 441 16.00 406 8.25 210 6.25 159 SD62 60A 60A 600V J 11.87 301 10.50 267 17.37 441 16.00 406 8.00 203 6.25 159 NE 100A (non) (non) - 11.87 301 10.12 257 17.37 441 15.62 397 4.25 108 7.50 191 SE263 100A 100A 250V H,K,R 11.87 301 10.12 257 17.37 441 15.62 397 9.00 229 7.50 191 SE263 100A 100A 600V H,K,R 11.87 301 10.12 257 17.37 441 15.62 397 9.00 229 7.50 191 SE263 100A 100A 600V J 11.87 301 10.12 257 17.37 441 15.62 397 7.75 197 7.50 191 NF 200A (non) (non) - 11.87 301 8.12 206 17.37 441 13.62 346 13.25 337 10.25 260 SF264 200A 200A 250V H,K,R 11.87 301 8.12 206 17.37 441 13.62 346 13.25 337 10.25 260 SF264 200A 200A 600V H,K,R 11.87 301 8.12 206 17.37 441 13.62 346 13.25 337 10.25 260 C371 Disconnect Mechanism Cutler-Hammer Mechanism for Circuit Breakers Circuit Breaker Type Enclosure Height Amp 72 Manufacturer Frame(s) 84 A B A B C D in. mm in. mm in. mm in. mm in. mm in. mm 11.87 301 11.62 295 17.37 441 17.12 435 6.00 152 5.75 146 210 C371E 150A Cutler-Hammer HMCP,FS,FH C371F (1) C371F (1) 225A Cutler-Hammer HMCP,JS,JH,JL 11.87 301 11.50 292 17.37 441 17.00 432 11.00 279 8.25 400A Cutler-Hammer HMCP,KS,KH 11.87 301 11.00 279 17.37 441 16.50 419 9.75 248 8.25 210 C371G (2) C371K (3) 600A Cutler-Hammer LS,LH 11.87 301 9.37 238 17.37 441 14.87 378 8.50 216 12.00 305 800A Cutler-Hammer MS,MH * * * * 17.37 441 11.37 289 10.25 260 12.00 305 C371K (3) 1200A Cutler-Hammer NS,NH * * * * 17.37 441 11.37 289 10.25 260 12.00 305 C371E 150A Westinghouse F(series C) 11.87 301 11.62 295 17.37 441 17.12 435 6.00 152 5.75 146 C371F (1) C371F (1) 250A Westinghouse J(series C) 11.87 301 11.50 292 17.37 441 17.00 432 9.00 229 8.25 210 400A Westinghouse K(series C) 11.87 301 11.00 279 17.37 441 16.50 419 9.75 248 8.25 210 C371G (2) C371K (3) 600A Westinghouse LA,LC 11.87 301 9.37 238 17.37 441 14.87 378 8.50 216 12.00 305 800A Westinghouse MC * * * * 17.37 441 11.37 289 10.25 260 12.00 305 C371K (3)(4) 1200A Westinghouse NC * * * * 17.37 441 11.37 289 10.25 260 12.00 305 * Do not install disconnects in this height enclosure. (1) (2) (3) (4) Wire bending space "B" does not allow the use of cable larger than 300 MCM in 72H enclosures. Wire bending space "B" does not allow the use of cable larger than 250 MCM in 72H enclosures. Wire bending space "B" does not allow the use of cable larger than 300 MCM in 84H enclosures. Wire bending space "B" does not allow the use of Westinghouse terminals TA1201NB1 in 84H enclosures. The dimensional information provided in this table is derived from information supplied by the manufacturer of the equipment to be installed. Fit and function of all equipment should be checked before and after installation to assure proper and safe operation and compliance with the applicable regulations, codes and standards. Notes: Refer to detail sheet for drawing information and associated dimensions. Dimensions are in inches. Millimeters shown are for reference only. Data subject to change without notice. 263 Modular Encl. Cutler-Hammer Mechanism for Switches Type 12 Modular Enclosures Type 12 Free-Standing Modular Enclosure Disconnects General Electric(R) Modular Encl. TDA Disconnect Mechanism General Electric Mechanism for Switches Fuse Clip Rating Amp Fuse Enclosure Height 72 Class Amp Volt 84 A B A B C D in. mm in. mm in. mm in. mm in. mm in. mm TDOM1A 30A (non) (non) - 11.87 301 12.37 314 17.37 441 17.87 454 7.00 178 5.50 140 TDOM1A 30A 30A 250V H,R 11.87 301 12.37 314 17.37 441 17.87 454 7.00 178 5.50 140 TDOM1B 30A 30A 600V H,R 11.87 301 12.37 314 17.37 441 17.87 454 11.50 292 5.50 140 TDOM1B 30A 60A 250V H,R 11.87 301 12.37 314 17.37 441 17.87 454 11.50 292 5.50 140 TDOM1B 30A 60A 600V H,R 11.87 301 12.37 314 17.37 441 17.87 454 11.50 292 5.50 140 TDOM1A 60A (non) (non) - 11.87 301 12.37 314 17.37 441 17.87 454 7.00 178 5.50 140 TDOM1B 60A 60A 250V H,R 11.87 301 12.37 314 17.37 441 17.87 454 11.50 292 5.50 140 TDOM1B 60A 60A 600V H,R 11.87 301 12.37 314 17.37 441 17.87 454 11.50 292 5.50 140 TDOM1B 60A 100A 250V H,R 11.87 301 12.37 314 17.37 441 17.87 454 11.50 292 5.50 140 TDOM1B 60A 100A 600V H,R 11.87 301 12.37 314 17.37 441 17.87 454 11.50 292 5.50 140 TDOM1A 100A (non) (non) - 11.87 301 12.37 314 17.37 441 17.87 454 7.00 178 5.5 140 TDOM1B 100A 100A 250V H,R 11.87 301 12.37 314 17.37 441 17.87 454 11.50 292 5.50 140 TDOM1B 100A 100A 600V H,R 11.87 301 12.37 314 17.37 441 17.87 454 11.50 292 5.50 140 TDOM1B 100A 200A 250V H,R 11.87 301 12.37 314 17.37 441 17.87 454 11.50 292 5.50 140 TDOM1B 100A 200A 600V H,R 11.87 301 12.37 314 17.37 441 17.87 454 11.50 292 5.50 140 TDOM2 200A (non) (non) - 11.87 301 9.75 248 17.37 441 15.25 387 7.00 178 9.25 235 TDOM2 200A 200A 250V H,R 11.87 301 9.75 248 17.37 441 15.25 387 15.50 394 9.25 235 TDOM2 200A 200A 600V H,R 11.87 301 9.75 248 17.37 441 15.25 387 15.50 394 9.25 235 General Electric Mechanism for Circuit Breakers Enclosure Height Amp Circuit Breaker Type 72 84 A B A B C D in. mm in. mm in. mm in. mm in. mm in. mm 140 TDOM1A 150A TEB, TEC, TED, THED 11.87 301 11.25 286 17.37 441 16.75 425 7.00 178 5.50 TDOM1B 150A TB1, TEC, TECL 11.87 301 11.25 286 17.37 441 16.75 425 11.50 292 5.50 140 TDOM1C 150A TEL 11.87 301 11.25 286 17.37 441 16.75 425 7.00 178 5.50 140 TDOM1D 150A THCL1 11.87 301 9.87 251 17.37 441 15.37 390 7.00 178 5.50 140 TDOM3 225A TFJ, TFK, THFK, TFL 11.87 301 10.87 276 17.37 441 16.37 416 10.50 267 6.00 152 TDOM4 400A TJJ, TJK4, THJK4, TJL4V 11.87 301 10.00 254 17.37 441 15.50 394 8.25 210 9.50 241 TDOM4 600A TJK6, THJK6, TJ4V, TJL4V 11.87 301 10.00 254 17.37 441 15.50 394 8.25 210 9.50 241 TDOM5 400A TB4, TJH6S 11.87 301 10.00 254 17.37 441 15.50 394 14.25 362 9.50 241 TDOM6 225A TLB2, THLC2 * * * * 17.37 441 14.87 378 11.75 298 9.50 241 TDOM6 400A TLB4, THLC4 * * * * 17.37 441 13.50 343 11.75 298 9.50 241 TDOM7 600A TB6 * * * * 17.37 441 11.75 298 18.25 464 9.50 241 TDOM7 800A TB8 * * * * 17.37 441 11.75 298 18.25 464 9.50 241 * Do not install disconnects in this height enclosure. The dimensional information provided in this table is derived from information supplied by the manufacturer of the equipment to be installed. Fit and function of all equipment should be checked before and after installation to assure proper and safe operation and compliance with the applicable regulations, codes and standards. Notes: Refer to detail sheet for drawing information and associated dimensions. Dimensions are in inches. Millimeters shown are for reference only. Data subject to change without notice. 264 Type 12 Modular Enclosures Type 12 Free-Standing Modular Enclosure Disconnects I-T-E Siemens(R) MAX-FLEX Disconnects I-T-E Siemens Circuit Mechanism Breaker Circuit Breakers Frame Enclosure Height Amp Device in. 18 18 24 A Height C 72 mm 84 nom in. mm in. mm in. mm D min in. 36 FHOE036 ED 125A 6.37 162 11.87 301 17.37 441 5.37 136 36 FHOE036 CED 125A 9.62 244 11.87 301 17.37 441 8.50 216 .06 36 FHOF036 FD 250A 9.50 241 11.87 301 17.37 441 5.62 143 2.43 36 FHOF036 CFD 250A 14.12 359 11.87 301 17.37 441 10.25 260 36 FHOJ036 JD,LD 400A,600A 11.00 279 11.87 301 17.37 441 36 FHOJ036 CJD 400A,600A 17.87 454 11.87 301 48 * ED 125A 6.37 162 11.87 301 48 * CED 125A 9.62 244 11.87 301 48 * FD 250A 9.50 241 11.87 301 48 * CFD 250A 14.12 359 11.87 48 * JD,LD 400A,600A 11.00 279 48 * CJD 400A,600A 17.87 454 48 FHON048 MD,ND 800A,1200A 16.00 406 48 * ED 125A 48 * CED 48 * FD 48 * CFD 48 * 48 * 48 FHON048 max mm -2.75 -70 in. mm min in. mm max in. mm 13.50 343 3.00 76 9.75 248 15 16.87 428 3.00 76 9.75 248 62 13.87 352 4.50 114 8.50 216 7.25 184 18.62 473 4.50 114 8.50 216 5.25 133 -2.87 -73 13.43 341 7.50 191 10.12 257 17.37 441 12.12 308 4.12 105 20.37 517 7.50 114 10.12 257 17.37 441 5.37 136 -15.37 -390 26.25 667 3.00 76 24.43 621 17.37 441 8.50 216 -12.00 -305 26.50 673 4.50 114 24.43 621 17.37 441 5.62 143 -12.15 -309 26.50 673 4.50 114 23.00 584 301 17.37 441 10.25 260 -10.25 -260 30.37 771 4.50 114 23.00 584 11.87 301 17.37 441 26.12 663 7.50 191 24.50 622 11.87 301 17.37 441 12.12 308 -8.50 -216 33.00 838 7.50 191 24.50 622 11.87 301 17.37 441 8.12 206 -5.12 -130 21.43 544 9.00 229 20.50 521 6.37 162 11.87 301 17.37 441 5.37 136 -13.37 -340 23.25 591 3.00 76 20.62 524 125A 9.62 244 11.87 301 17.37 441 8.50 216 -10.00 -254 26.50 673 3.00 76 20.62 254 250A 9.50 241 11.87 301 17.37 441 5.62 143 -13.00 -330 23.50 597 4.50 114 19.37 492 250A 14.12 359 11.87 301 17.37 441 10.25 260 -8.25 -210 28.37 721 4.50 114 19.37 492 JD,LD 400A,600A 11.00 279 11.87 301 17.37 441 5.25 133 -13.43 -343 23.12 587 7.50 191 20.93 532 CJD 400A,600A 17.87 454 11.87 301 17.37 441 12.12 308 -6.50 -165 30.00 762 7.50 191 20.93 532 MD,ND 800A,1200A 16.00 406 11.87 301 17.37 441 -3.12 -79 19.93 506 9.00 229 20.50 521 5.25 133 -15.43 -392 8.12 206 MAX-FLEX Disconnect Mechanism Disconnect Mechanism Cable Length Circuit Breaker Type FHOE036 36 ED2 ,ED4, ED6, HED4, HED6, ED6ETI FHOE036 36 CED6, CED6ETI FHOF036 36 FD6, FXD6, HFD6, FXD6ETI FHOF036 36 CFD6, CFD6ETI FHOJ036 36 JD2, JD6, JXD6, HJD6, JXD6ETI, LD6, LXD6, HLD6, LXD6ETI, SHJD6, SLD6, SHLD6 FHOJ036 36 CJD6, CJD6ETI, CLD6, CLD6ETI, SCJD6, SCLD6 FHON048 48 MD6, HMD6, CMD6, MXD6ETI, CMD6ETI, SMD6, SHMD6, SCMD6, ND6, HND6, CND6, SND6, SCND6 * Non-standard mechanism with 48 inch operating cable must be specified. (1) Flexible operating cable allows disconnect to be mounted within minimum and maximum of "C" dimension when "D" is minimum. (2) Flexible operating cable allows disconnect to be mounted within minimum and maximum of "D" dimension when "C" is nominal. The dimensional information provided in this table is derived from information supplied by the manufacturer of the equipment to be installed. Fit and function of all equipment should be checked before and after installation to assure proper and safe operation and compliance with the applicable regulations, codes and standards. Notes: Refer to detail sheet for drawing information and associated dimensions. Flexible cable allows for variable disconnect mounting and adequate wire bending space must be maintained Dimensions are in inches. Millimeters shown are for reference only. Data subject to change without notice. 265 Modular Encl. Enclosure Cable Type 12 Modular Enclosures Type 12 Free-Standing Modular Enclosure Disconnects Square D(R) Modular Encl. 9422 Disconnect Mechanism Square D Mechanism for Switches Fuse Clip Rating Amp Fuse Enclosure Height 72 Class Amp Volt 84 A B A B C in. mm in. mm in. mm in. mm in. D mm in. mm RC-1 30A (non) (non) - 11.87 301 11.75 298 17.37 441 17.18 436 3.25 83 7.25 1842 RC-2 30A 30A 250V H,K,R 11.87 301 11.75 298 17.37 441 17.18 436 5.00 127 7.25 1842 RC-3 30A 30A 600V H,K,R 11.87 301 11.75 298 17.37 441 17.18 436 8.00 203 7.25 1842 RC-3 30A 30A 600V J 11.87 301 11.75 298 17.37 441 17.18 436 5.00 127 7.25 1842 RC-3 30A 60A 250V H,K,R 11.87 301 11.75 298 17.37 441 17.18 436 6.00 152 7.25 1842 TC-1 30A (non) (non) - 11.87 301 9.87 251 17.37 441 15.37 390 5.75 146 6.25 159 TC-2 30A 30A 250V H,K,R 11.87 301 9.87 251 17.37 441 15.37 390 5.75 146 6.25 159 TC-3 30A 30A 600V H,K,R 11.87 301 9.87 251 17.37 441 15.37 390 7.75 197 6.25 159 TC-3 30A 30A 600V J 11.87 301 9.87 251 17.37 441 15.37 390 5.75 146 6.25 159 TC-3 30A 60A 250V H,K,R 11.87 301 9.87 251 17.37 441 15.37 390 6.00 152 6.25 159 TD-1 60A (non) (non) - 11.87 301 10.75 273 17.37 441 16.25 413 6.50 165 6.75 171 TD-2 60A 30A 600V H,K,R 11.87 301 10.75 273 17.37 441 16.25 413 8.50 216 6.75 171 TD-2 60A 60A 250V H,K,R 11.87 301 10.75 273 17.37 441 16.25 413 6.50 165 6.75 171 TD-3 60A 60A 600V H,K,R 11.87 301 10.75 273 17.37 441 16.25 413 9.00 229 6.75 171 TD-3 60A 60A 600V J 11.87 301 10.75 273 17.37 441 16.25 413 6.50 165 6.75 171 TE-1 100A (non) (non) - 11.87 301 10.50 267 17.37 441 16.00 406 4.75 257 8.50 216 TE-2 100A 100A 250V H,K,R 11.87 301 10.50 267 17.37 441 16.00 406 7.50 191 8.50 216 TE-2 100A 100A 600V H,K,R 11.87 301 10.50 267 17.37 441 16.00 406 9.50 241 8.50 216 TE-2 100A 100A 600V J 11.87 301 10.50 267 17.37 441 16.00 406 6.25 159 8.50 216 TE-3 100A 200A 600V J 11.87 301 10.50 267 17.37 441 16.00 406 13.75 349 8.50 216 TF-1 200A (non) (non) - 11.87 301 9.12 232 17.37 441 14.62 371 5.50 140 11.75 298 TF-2 200A 200A 250V H,K,R 11.87 301 9.12 232 17.37 441 14.62 371 11.50 62 11.75 298 TF-2 200A 200A 600V H,K,R 11.87 301 9.12 232 17.37 441 14.62 371 14.00 356 11.75 298 TF-2 200A 200A 600V J 11.87 301 9.12 232 17.37 441 14.62 371 10.25 260 11.75 298 TF-3 200A 400A 600V J 11.87 301 9.12 232 17.37 441 14.62 371 14.50 368 11.75 298 Square D Mechanism for Circuit Breakers Amp Enclosure Height Circuit Breaker Type 72 84 A B A B C D in. mm in. mm in. mm in. mm in. mm in. mm 140 RN-1 100A FAL, FHL, FCL 7.87 200 6.87 174 17.37 441 16.37 416 5.25 133 5.50 RP-1 250A KAL, KHL, KCL 7.87 200 6.62 168 17.37 441 17.12 435 7.25 184 5.75 146 RR-1 400A LAL, LHL, Q4L * * * * 17.37 441 12.75 324 7.75 197 9.00 229 RR-2 400A ILL * * * * 17.37 441 17.12 435 11.00 279 15.75 400 RT-1 800A MEL * * * * 17.37 441 12.62 321 9.25 235 12.00 305 RT-1 1000A MAL, MHL * * * * 17.37 441 12.62 321 9.25 235 12.00 305 * Do not install disconnects in this height enclosure. The dimensional information provided in this table is derived from information supplied by the manufacturer of the equipment to be installed. Fit and function of all equipment should be checked before and after installation to assure proper and safe operation and compliance with the applicable regulation, codes and standards. Notes: Refer to detail sheet for drawing information and associated dimensions. Dimensions are in inches. Millimeters shown are for reference only. Data subject to change without notice. 266 Type 12 Modular Enclosures Type 12 Free-Standing Modular Enclosure Disconnects Westinghouse(R) AMT Disconnect Mechanism Fuse Clip Rating Amp Fuse Enclosure Height 60 Class Amp Volt Pivot Width 72 A B C A D B variable fixed in. mm in. mm in. mm in. mm in. mm in. mm in mm - 13.12 333 13.25 337 18.62 473 18.75 476 5.25 133 9.00 229 7.00 178 178 DS16U 30A (non) (non) DS121R 30A 30A 250V H,R 13.12 333 13.25 337 18.62 473 18.75 476 10.25 260 9.00 229 7.00 DS161U 30A 30A 600V H,J,R 13.12 333 13.25 337 18.62 473 18.75 476 12.25 311 9.00 229 7.00 178 DS122 30A 60A 250V H,R 13.12 333 13.25 337 18.62 473 18.75 476 10.25 260 9.00 229 7.00 178 DS162 30A 60A 600V H,J,R 13.12 333 13.25 337 18.62 473 18.75 476 12.25 311 9.00 229 7.00 178 DS26U 60A (non) (non) - 13.12 333 13.25 337 18.62 473 18.75 476 5.25 133 9.00 229 7.00 178 DS222R 60A 60A 250V H,R 13.12 333 13.25 337 18.62 473 18.75 476 10.25 260 9.00 229 7.00 178 DS262R 60A 60A 600V H,J,R 13.12 333 13.25 337 18.62 473 18.75 476 12.25 311 9.00 229 7.00 178 DS263 60A 100A 250V H,R 13.12 333 13.25 337 18.62 473 18.75 476 10.25 260 9.00 229 7.00 178 178 DS263 60A 100A 600V H,J,R 13.12 333 13.25 337 18.62 473 18.75 476 12.25 311 9.00 229 7.00 DS36U 100A (non) (non) - 13.12 333 13.25 337 18.62 473 18.75 476 5.25 133 9.00 229 7.00 178 DS363R 100A 100A 250V H,R 13.12 333 13.25 337 18.62 473 18.75 476 10.25 260 9.00 229 7.00 178 DS363R DS364 (1) 100A 100A 600V H,J,R 13.12 333 13.25 337 18.62 473 18.75 476 12.25 311 9.00 229 7.00 178 100A 200A 250V H,R 13.12 333 13.25 337 18.62 473 18.75 476 5.25 133 9.00 229 7.00 178 DS364 (1) 100A 200A 600V H,J,R 13.12 333 13.25 337 18.62 473 18.75 476 5.25 133 9.00 229 7.00 178 DS46U 200A (non) (non) - 13.12 333 11.00 279 18.62 473 16.50 419 6.00 152 12.00 305 10.00 254 DS464R 200A 200A 250V H,R 13.12 333 11.00 279 18.62 473 16.50 419 14.00 356 12.00 305 10.00 254 DS464R 200A 200A 600V H,R 13.12 333 11.00 279 18.62 473 16.50 419 15.25 387 12.00 35 10.00 254 DS464R DS465 (1) 200A 200A 600V J 13.12 333 11.00 279 18.62 473 16.50 419 14.00 356 12.00 305 10.00 254 200A 400A 250V H,J,R 13.12 333 11.00 279 18.62 473 16.50 419 6.00 152 12.00 305 10.00 254 DS465 (1) 200A 400A 600V H,J,R 13.12 333 11.00 279 18.62 473 16.50 419 6.00 152 12.00 305 10.00 254 Westinghouse Mechanism for Amp Circuit Breakers EB 100A Enclosure Height Circuit Breaker Type 72 Pivot Width 84 A B C A D B variable fixed in. mm in. mm in. mm in. mm in. mm in. mm in mm EB 13.12 333 12.37 314 18.62 473 17.87 454 5.50 140 9.25 235 7.25 184 FB Tri-Pac 100A FB Tri-Pac 13.12 333 12.37 314 18.62 473 17.87 454 8.25 210 9.25 235 7.25 184 MCP 150A MCP (0-4) current limiting 13.12 333 12.37 314 18.62 473 17.87 454 8.25 210 9.25 235 7.25 184 F Frame 150A F (series C) 13.12 333 12.37 314 18.62 473 17.87 454 5.50 140 9.25 235 7.25 184 J Frame 250A J (series C) 13.12 333 9.50 241 18.62 473 15.00 381 6.75 36 9.25 235 - K Frame 400A K (series C) 13.12 333 9.00 229 18.62 473 14.50 368 8.25 210 9.25 235 - - LA Tri-Pac 400A LA Tri-Pac * * * * 18.62 473 16.50 419 14.25 362 12.00 305 - - LA, LC 600A LA, LAB, HLA, LC, HLC 13.12 333 11.00 279 18.62 473 16.50 419 9.00 229 12.00 305 - - MC 800A MC, HMC * * * * 18.62 473 12.87 327 10.50 267 12.00 305 - - - NB Tri-Pac 800A NB Tri-Pac * * * * 18.62 473 12.87 327 10.50 267 12.00 305 - - NB, NC 1200A NB, HNB, NC, HNC * * * * 18.62 473 12.87 327 10.50 267 12.00 305 - - * Do not install disconnects in this height enclosure. (1) Dimensions "C" and "D" on these disconnects do not include space for fuse blocks which are mounted separately. The dimensional information provided in this table is derived from information supplied by the manufacturer of the equipment to be installed. Fit and function of all equipment should be checked before and after installation to assure proper and safe operation and compliance with the applicable regulation, codes and standards. Notes: Refer to detail sheet for drawing information and associated dimensions. Dimensions are in inches. Millimeters shown are for reference only. Data subject to change without notice. 267 Modular Encl. Westinghouse Mechanism for Switches Type 12 Modular Enclosures Type 12 Free-Standing Modular Enclosure Disconnects Westinghouse Modular Encl. SM Disconnect Mechanism Westinghouse Mechanism for Switches Amp Fuse Clip Rating Switch Type Fuse Enclosure Height 72 Class 84 A B A B C D in. mm in. mm in. mm in. mm in. mm in. mm SM100R 30A De-ion Switch - 11.31 287 11.25 286 16.81 427 16.75 425 6.62 168 4.75 121 SM100R 60A De-ion Switch - 11.31 287 11.25 286 16.81 427 16.75 425 6.62 168 4.75 121 SM100R 100A De-ion Switch - 11.31 287 9.75 248 16.81 427 15.25 387 6.62 168 5.25 121 SM100SFR 30A DS121R H,R 11.31 287 11.50 292 16.81 427 17.00 432 7.00 178 5.50 140 SM100SFR 30A DS122 H,R 11.31 287 11.50 292 16.81 427 17.00 432 7.87 200 5.50 140 SM100SFR 60A DS222R H,R 11.31 287 11.50 292 16.81 427 17.00 432 7.87 200 5.50 140 SM100SFR 30A DS161R H,R 11.31 287 11.50 292 16.81 427 17.00 432 10.00 254 5.50 140 SM100SFR 30A DS161R J 11.31 287 11.50 292 16.81 427 17.00 432 7.25 184 5.50 140 SM100SFR 60A DS262H J 11.31 287 11.50 292 16.81 427 17.00 432 7.25 184 5.50 140 SM100SFR 30A DS162 H,R 11.31 287 11.50 292 16.81 427 17.00 432 10.37 263 5.50 140 SM100SFR 60A DS262R H,R 11.31 287 11.50 292 16.81 427 17.00 432 10.37 263 5.50 140 SM100SFR 100A DS363R(250V) H,R 11.31 287 11.50 292 16.81 427 17.00 432 10.25 260 5.50 140 SM100SFR 100A DS363R(600V) H,R 11.31 287 11.50 292 16.81 427 17.00 432 12.12 308 5.50 140 SM100SFR 60A DS263(600V) H,R 11.31 287 11.50 292 16.81 427 17.00 432 12.12 308 5.50 140 SM100SFR 100A DS363R J 11.31 287 11.50 292 16.81 427 17.00 432 8.87 225 5.50 140 SM150R 30A DS16U Switch - 11.31 287 11.50 292 16.81 427 17.00 432 5.12 130 5.50 140 SM150R 60A DS26U Switch - 11.31 287 11.50 292 16.81 427 17.00 432 5.12 130 5.50 140 SM150R (1) SM150R (1) 100A DS36U Switch - 11.31 287 11.50 292 16.81 427 17.00 432 5.12 130 5.50 140 100A DS364 H,R 11.31 287 11.50 292 16.81 427 17.00 432 5.12 130 5.50 140 SM200SR (1) SM200SR (1) 200A DS46U Switch - 10.87 276 9.00 229 16.37 416 14.50 368 7.37 187 6.75 171 200A DS465 Switch H,R 10.87 276 9.00 229 16.37 416 14.50 368 7.37 187 6.75 171 SM200SFR 200A DS464R H,R 10.87 276 9.00 229 16.37 416 14.50 368 15.25 387 6.75 171 Westinghouse Mechanism for Circuit Breakers Enclosure Height Amp Circuit Breaker Type 72 84 A B A B C D in. mm in. mm in. mm in. mm in. mm in. mm SM150R 100A EB 11.31 287 10.50 267 16.81 427 16.00 406 5.12 130 5.50 140 SM101PR 100A FB Tri-Pac 11.31 287 10.50 267 16.81 427 16.00 406 8.00 203 5.50 140 SM101PR 150A MCP (0-4) current limiting 11.31 287 10.50 267 16.81 427 16.00 406 8.00 203 5.50 140 SM150R 150A F (series C) 11.31 287 10.50 267 16.81 427 16.00 406 8.00 203 5.50 140 SM250JR 250A J (series C) 10.87 276 8.00 203 16.37 416 13.50 343 8.50 216 7.50 191 SM400KR 400A K (series C) 10.87 276 7.62 194 16.37 416 13.12 333 9.12 232 7.50 191 SM400PR 400A LA Tri-Pac 10.87 276 7.75 197 16.37 416 13.25 337 14.50 368 9.75 248 SM400R 600A LA, LAB, HLA, LC, HLC 10.87 276 7.75 197 16.37 416 13.25 337 9.25 50 9.75 248 SM400R 600A LA, LAB, HLA, LC, HLC 10.87 276 7.75 197 16.37 416 13.25 337 9.25 50 9.75 248 SM800R 800A MC, HMCL * * * * 16.37 416 9.62 244 10.75 581 9.75 248 SM400PR 800A NB, Tri-Pac * * * * 16.37 416 9.62 244 16.87 428 9.75 248 SM1200R 1200A NB, HNB, NC, HNC * * * * 16.37 416 9.62 244 10.75 581 9.75 248 * Do not install disconnects in this height enclosure. (1) Dimensions "C" and "D" on these disconnects do not include space for fuse blocks which are mounted separately. The dimensional information provided in this table is derived from information supplied by the manufacturer of the equipment to be installed. Fit and function of all equipment should be checked before and after installation to assure proper and safe operation and compliance with the applicable regulation, codes and standards. Notes: Refer to detail sheet for drawing information and associated dimensions. Dimensions are in inches. Millimeters shown are for reference only. Data subject to change without notice. 268 Type 12 Modular Enclosures Type 12 Free-Standing Modular Enclosure Disconnects Disconnect Ordering Information General Electric Standard enclosures designed to accept variable depth type 1494V. Standard enclosures designed to accept variable depth type TDA. Allen-Bradley 1494V disconnect switch: General Electric TDA disconnect switch: 1. Disconnect switch 2. Operating mechanism 3. Operating handle 4. Fuse block kit, (if required) 5. Fuse clip kit, (if required) 6. Line and load connectors, (if necessary) 7. Connecting rod 1. Disconnect switch, (QMR, QMW) 2. Operating mechanism 3. Operating handle TDA1 4 Fuse clip kit or no-fuse kit, (if required) 5. Line and load connectors, (if necessary) 6. Extended length drive rod, (if required) NOTE: These items can be ordered as an assembly. Allen-Bradley 1494V circuit breaker: General Electric TDA circuit breaker: 1. Circuit breaker (General Electric, Westinghouse) 2. Operating mechanism 3. Operating handle 4. Line and load connectors, (if necessary) 5. Connecting rod 1. Circuit breaker 2. Operating mechanism 3. Operating handle TDA1 4. Line and load connectors, (if necessary) 5. Extended length drive rod, (if required) Standard enclosures designed to accept fixed depth type 1494F or 1494D. Allen-Bradley 1494F disconnect switch: I-T-E Siemens Standard enclosures designed to accept MAX-FLEX type FHO. 1. Disconnect switch 2. Operating mechanism 3. Operating handle 4. Fuse block kit, (if required) 5. Fuse clip kit, (if required) 6. Line and load connectors, (if necessary) I-T-E MAX-FLEX circuit breaker: 1. Circuit breaker 2. Operating mechanism 3. Operating handle 4. Line and load connectors, (if necessary) 5. Operating cable NOTE: Items 2,3 and 5 can be ordered as an assembly, standard with a 36 inch long operating cable. All 24 inch deep enclosures require a 48 inch long cable. Allen-Bradley 1494D circuit breaker: 1. Circuit breaker (General Electric, Westinghouse) 2. Operating mechanism 3. Operating handle 4. Line and load connectors, (if necessary) 5. Slide mechanism Square D Standard enclosures designed to accept variable depth type 9422. Cutler-Hammer Standard enclosures designed to accept variable depth type C361 or C371. Cutler-Hammer C361 disconnect switch: 1. Disconnect switch 2. Operating mechanism 3. Operating handle 4. Fuse clip kit (if required) 5. Line and load connectors (if necessary) Square D 9422 disconnect switch: 1. Disconnect switch 2. Operating mechanism 3. Operating handle 4. Fuse clip kit, (if required) 5. Line and load connectors, (if necessary) 6. Connecting rod Square D 9422 circuit breaker: NOTE: Items 1,2 and 3 can be ordered as an assembly. Cutler-Hammer C371 circuit breaker: 1. Circuit breaker (Cutler-Hammer, Westinghouse) 2. Operating mechanism 3. Operating handle 4. Line and load connectors (if necessary) NOTE: Items 2 and 3 can be ordered as an assembly. 269 1. Circuit breaker 2. Operating mechanism 3. Operating handle 4. Line and load connectors, (if necessary) 5. Connecting rod Modular Encl. Allen-Bradley Type 12 Modular Enclosures Type 12 Free-Standing Modular Enclosure Disconnects Disconnect Ordering Information Modular Encl. Westinghouse Standard enclosures designed to accept below handle type AMT. Westinghouse AMT disconnect switch: 1. Disconnect switch 2. Pivot mechanism assembly for below handle mounting 3. Backplate and yoke assembly for below handle mounting 4. Operating handle 5. Fuse block kit, (if required) 6. Fuse clip kit (if required) 7. Line and load connectors, (if necessary) 8. Connecting rod Westinghouse AMT circuit breaker: 1. Circuit breaker 2. Pivot mechanism assembly for below handle mounting 3. Backplate and yoke assembly for below handle mounting 4. Operating handle 5. Line and load connectors, (if necessary) 6. Fuse clip kit, (if required) 7. Connecting rod Standard enclosures designed to accept fixed depth type SM. Westinghouse SM disconnect switch: 1. Disconnect switch 2. Operating mechanism 3. Operating handle 4. Fuse block kit, (if required) 5. Fuse clip kit, (if required) 6. Line and load connectors, (if necessary) Important Note When ordering modular flange-mounted disconnect equipment, be sure to include all necessary components listed below. 1. Enclosure includes the following equipment: Enclosure door locking handle and rods Door interlocking system Interlocking connecting rod Adjustable bracket, (see note 4) 2. Operator adapter plate, gasket and hardware for the type of disconnect device being used MUST be ordered separately (see page 381) 3. Modular gasket kits and/or end plates (see page 259) 4. 24 inch deep enclosures include an adjustable bracket for mounting some disconnects: Cutler-Hammer C361 device Cutler-Hammer C371 E and F devices unless long connecting rod C371CS1 is specified Cutler-Hammer C371 G and K devices unless long connecting rod C371CS2 is specified General Electric TDA device unless extended length rod TDSR is specified Square D 9422 device unless extra long connecting rod 9422-R2 is specified Note: Some devices require two rods, consult the device manufacturer (Westinghouse AMT below handle device) 5. Disconnects and related components are available from the manufacturer 6. The disconnect ordering information provided is derived from information supplied by the manufacturer of the equipment to be installed. Fit and function of all equipment should be checked before and after installation to assure proper and safe operation and compliance with the applicable regulations, codes and standards. Westinghouse SM circuit breaker: 1. Circuit breaker 2. Operating mechanism 3. Operating handle 4. Line and load connectors, (if necessary) 270