POWER ENTRY MODULES
56
Combination
NOTE: Other combinations of terminals may be specified on special order.
Features:
• RFI Filter Module Combines IEC Connector, Fusing,
Optional Voltage Select and On/Off Switch into a
Single, Space-Efficient Assembly
• Enhanced Low Frequency Response with No
Resonant Peaks
• Fully Shielded for Radiative Noise Control
• Accepts Either U.S. or European Standard Fuse
Sizes. Dual or Single Power Line Fusing
Specifications:
Rated Voltage: 250VAC Maximum - 50/60 Hz
Rated Current: 115VAC 250VAC
10A 10A
Current Overload: 6X for 8 seconds
Hi-Pot Test (1 min):
Line to Ground 1500VAC
Line to Line 2250VDC
Insulation Resistance: 9 x 109 Ω at 100VDC
Ambient Temperature: 40°C Max at rated current
Humidity Range: 0% to 95% R.H.
Termination:
• QC – Quick Connect
• IEC Receptacle
Maximum Leakage Current:
Each Line to Ground PE1 PE1-PO
115VAC, 60Hz: 0.25mA 0.4mA
250VAC, 50Hz: 0.40mA .75mA
Voltage Select Card: Installed in 120VAC position
unless otherwise specified
Agency Approvals:
Nominal
Current
Rating
Part
Number Termination
Line/Load
MINIMUM INSERTION LOSS - dB (50 ohm Circuit)
MODE Frequency - MHz
.05 .15 .50 .10 5.0 10 30
10A
PE1XXX10 IEC/QC Common
Differential 10
10 20
20 30
30 38
35 45
55 50
60 50
55
PE1XXXP0 IEC/QC Common
Differential 13
10 24
20 33
30 38
35 48
65 54
65 54
55
PE1 Series
PE1 Series Simplified
Schematic without Voltage Selector
PE1 Series Simplified Schematic with Voltage Selector