PE1 Series Rated Voltage: 250VAC Maximum - 50/60 Hz Rated Current: 115VAC 250VAC 10A 10A Current Overload: 6X for 8 seconds Hi-Pot Test (1 min): Line to Ground 1500VAC Line to Line 2250VDC Insulation Resistance: 9 x 109 at 100VDC Ambient Temperature: 40C Max at rated current Humidity Range: 0% to 95% R.H. Termination: * QC - Quick Connect * IEC Receptacle Maximum Leakage Current: Each Line to Ground PE1 PE1-PO 115VAC, 60Hz: 0.25mA 0.4mA 250VAC, 50Hz: 0.40mA .75mA Voltage Select Card: Installed in 120VAC position unless otherwise specified Agency Approvals: * RFI Filter Module Combines IEC Connector, Fusing, Optional Voltage Select and On/Off Switch into a Single, Space-Efficient Assembly * Enhanced Low Frequency Response with No Resonant Peaks * Fully Shielded for Radiative Noise Control * Accepts Either U.S. or European Standard Fuse Sizes. Dual or Single Power Line Fusing FUSING 1 POLE 1 L 2 LINE PE1 Series Simplified Schematic without Voltage Selector L LOAD Features: 3 4 N N 2 POLE G G PE1 Series Simplified Schematic with Voltage Selector FUSING 1 POLE L L 1 110V 4 2 POLE G G LOAD 3 N N Nominal Current Rating 110V 2 LINE POWER ENTRY MODULES Combination Specifications: MINIMUM INSERTION LOSS - dB (50 ohm Circuit) Part Number Termination Line/Load MODE .05 .15 Frequency - MHz .50 .10 5.0 10 30 PE1XXX10 IEC/QC Common Differential 10 10 20 20 30 30 38 35 45 55 50 60 50 55 PE1XXXP0 IEC/QC Common Differential 13 10 24 20 33 30 38 35 48 65 54 65 54 55 10A NOTE: Other combinations of terminals may be specified on special order. 56 www.curtisind.com Curtis Industries A Division of Powers Holdings, Inc. Specifications subject to change. Dimensions are shown for reference purposes only. PE1 1.99 (50,5) (10Amp) Dimensions L I N E Refer to Standard Mounting Cutouts on Page 58 L O A D 2.41 (61,2) Max. 3.00 (76,2) 1.12 (28,4) 2.58 (65,5) Max. 1 3 2 How to Order PE1 X MOUNTING METHOD & FUSING 6 = Screw Mount Metric or U.S. Fuse* 8 = Screw Mount 2 Metric or U.S. Fuses * U.S. Fuse not available without voltage selector VOLTAGE SELECTOR 0 = No Selector 3 = 115-230 VAC Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents. X X 0 OPTIONS (Consult Factory) 1 = Standard Units P = High Performance Insertion Loss CURRENT RATING 0 = 10 AMP SWITCH 0 = No Switch 1 = SPST Rocker Switch 2 = DPST Rocker Switch Curtis Industries A Division of Powers Holdings, Inc. INSTALLATION INSTRUCTION IMPORTANT - CHANGING FUSE/VOLTAGE PE1 To change fuse, remove power cord. Remove voltage selector and replace fuse. Reinsert fuse holder. To change the operating voltage on the PE1 Series, remove the power cord and rotate fuse holder block until desired voltage aligns with the mark on the module housing. * Filter shipped without fuse. Always use caution when selecting and changing fuses and voltage requirements. Curtis Industries is not responsible for malfunction due to improper installation/selection of fuse and/or voltage select. 1-800-657-0853 POWER ENTRY MODULES SERIES PE = Power Entry PM = Medical Power Entry X WITH VOLTAGE SELECTOR Combination 3.20 (81,3) H 1.575 (40,01) 1.15 (29,2) Max. 4 57